Summary of Study ST000750
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000540. The data can be accessed directly via it's Project DOI: 10.21228/M8VT19 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST000750 |
Study Title | Rat amniotic fluid metabolomics (part II) |
Study Type | MS analysis |
Study Summary | Pregnant rats were treated for 5 days with 100mg/kg/day DEHP or vehicle control (corn oil) via a wafer which the rats consumed orally. After the fifth treatment, rats were euthanized and uterine horns were dissected. Amniotic fluid was collected from the gestational sac via syringe and collected into 1.5mL tubes. Tubes were then stored at -80 celsius. |
Institute | University of Michigan |
Department | Biomedical Research Core Facilities |
Laboratory | Metabolomics core |
Last Name | Kachman |
First Name | Maureen |
Address | 6300 Brehm Tower, 1000 Wall Street, Ann Arbor, MI 48105-5714 |
mkachman@med.umich.edu | |
Phone | (734) 232-8175 |
Submit Date | 2017-06-19 |
Num Groups | 2 |
Total Subjects | 10 |
Raw Data Available | Yes |
Raw Data File Type(s) | d |
Analysis Type Detail | LC-MS |
Release Date | 2017-12-06 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN001176 | AN001177 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Agilent | Agilent |
Column | Waters Acquity HSS T3 (50 x 2.1mm,1.8um) | Waters Acquity HSS T3 (50 x 2.1mm,1.8um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | Agilent 6530 QTOF | Agilent 6530 QTOF |
Ion Mode | NEGATIVE | POSITIVE |
Units | peak area | peak area |
MS:
MS ID: | MS001071 |
Analysis ID: | AN001176 |
Instrument Name: | Agilent 6530 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
Ion Mode: | NEGATIVE |
Analysis Protocol File: | A003_-_Untargeted_Metabolomics.pdf |
MS ID: | MS001072 |
Analysis ID: | AN001177 |
Instrument Name: | Agilent 6530 QTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
Ion Mode: | POSITIVE |
Analysis Protocol File: | A003_-_Untargeted_Metabolomics.pdf |