This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001215. The data can be accessed directly via it's Project DOI: 10.21228/M8NQ5X This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001925 |
Study Title | MS Untargeted Metabolomics from Human Serum |
Study Summary | Multiple Myeloma patients were treated with the proteasome inhibitor carfilzomib in different protocols according to their clinical stage. Paired serum samples were obtained before i.v injection and after 1-8h post treatment and snap frozen. Samples were stored at -80°C until analysis. |
Institute | University of Zurich |
Last Name | Mendez |
First Name | Max |
Address | Rorschacherstrasse 95. 9007, St.Gallen |
maxmendez@runbox.com | |
Phone | +41 71 494 10 67 |
Submit Date | 2021-09-21 |
Num Groups | 2 |
Total Subjects | 6 |
Num Males | 5 |
Num Females | 1 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Waters) |
Analysis Type Detail | LC-MS |
Release Date | 2022-01-02 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003128 | AN003129 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Waters Acquity | Waters Acquity |
Column | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | Waters Xevo-TQ | Waters Xevo-TQ |
Ion Mode | NEGATIVE | POSITIVE |
Units | m/z | m/z |
MS:
MS ID: | MS002908 |
Analysis ID: | AN003128 |
Instrument Name: | Waters Xevo-TQ |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | he additive ions when the substance is ionized at the ion source are negative ions such as COOH-, OH-. , the capillary and sampling cone voltages were set at 2.0 kV and 40.0 V, respectively. |
Ion Mode: | NEGATIVE |
MS ID: | MS002909 |
Analysis ID: | AN003129 |
Instrument Name: | Waters Xevo-TQ |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | The additive ions when the substance is ionized at the ion source are positive ions such as H+, NH4+, K+. , the capillary and sampling cone voltages were set at 3.0 kV and 40.0 V, respectively |
Ion Mode: | POSITIVE |