Summary of Study ST002044
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001291. The data can be accessed directly via it's Project DOI: 10.21228/M8V12R This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002044 |
Study Title | An observational study of cardiovascular patients in India |
Study Summary | Serum samples for CVD patients were analyzed by untargeted metabolomics assays to identify prognostic biomarkers. |
Institute | Translational Health Science And Technology Institute (THSTI) |
Last Name | Kumar |
First Name | Yashwant |
Address | NCR Biotech Science Cluster 3rd Milestone, Faridabad - Gurgaon Rd, Expressway, Faridabad, Haryana 121001, India |
yashubt@gmail.com | |
Phone | 0129-2876300 |
Submit Date | 2021-12-22 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzML |
Analysis Type Detail | LC-MS |
Release Date | 2022-02-08 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003325 | AN003326 | AN003327 | AN003328 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | HILIC | Reversed phase | Reversed phase |
Chromatography system | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | Waters Xbridge BEH HILIC (75 x 2.1mm,2.5um) | Waters Xbridge BEH HILIC (75 x 2.1mm,2.5um) | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Fusion Orbitrap | Thermo Fusion Orbitrap | Thermo Fusion Orbitrap | Thermo Fusion Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | peak height | peak height | peak height | peak height |
MS:
MS ID: | MS003095 |
Analysis ID: | AN003325 |
Instrument Name: | Thermo Fusion Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The electrospray ionization (ESI) source was operated for both positive mode (+) and negative (-) ionization at 120,000 resolution in MS1 mode and 30000 resolution in data-dependent MS2 scan mode. The spray voltage used for these positive and negative modes is 4000 and 35000 volts respectively. Sheath gas and auxiliary gas were set to 42 and 11 respectively. The mass scan range was 60-900 m/z, ACG (Automatic control gain) target at 100000 ions and maximum injection time was 50 ms for MS and ACG target was 20000 ions and maximum injection time 60 ms for MSMS was used. Data were processed using the IDSL.IPA software (https://cran.r-project.org/web/packages/IDSL.IPA/index.html) |
Ion Mode: | POSITIVE |
MS ID: | MS003096 |
Analysis ID: | AN003326 |
Instrument Name: | Thermo Fusion Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The electrospray ionization (ESI) source was operated for both positive mode (+) and negative (-) ionization at 120,000 resolution in MS1 mode and 30000 resolution in data-dependent MS2 scan mode. The spray voltage used for these positive and negative modes is 4000 and 35000 volts respectively. Sheath gas and auxiliary gas were set to 42 and 11 respectively. The mass scan range was 60-900 m/z, ACG (Automatic control gain) target at 100000 ions and maximum injection time was 50 ms for MS and ACG target was 20000 ions and maximum injection time 60 ms for MSMS was used. Data were processed using the IDSL.IPA software (https://cran.r-project.org/web/packages/IDSL.IPA/index.html) |
Ion Mode: | NEGATIVE |
MS ID: | MS003097 |
Analysis ID: | AN003327 |
Instrument Name: | Thermo Fusion Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The electrospray ionization (ESI) source was operated for both positive mode (+) and negative (-) ionization at 120,000 resolution in MS1 mode and 30000 resolution in data-dependent MS2 scan mode. The spray voltage used for these positive and negative modes is 4000 and 35000 volts respectively. Sheath gas and auxiliary gas were set to 42 and 11 respectively. The mass scan range was 60-900 m/z, ACG (Automatic control gain) target at 100000 ions and maximum injection time was 50 ms for MS and ACG target was 20000 ions and maximum injection time 60 ms for MSMS was used. Data were processed using the IDSL.IPA software (https://cran.r-project.org/web/packages/IDSL.IPA/index.html) |
Ion Mode: | POSITIVE |
MS ID: | MS003098 |
Analysis ID: | AN003328 |
Instrument Name: | Thermo Fusion Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The electrospray ionization (ESI) source was operated for both positive mode (+) and negative (-) ionization at 120,000 resolution in MS1 mode and 30000 resolution in data-dependent MS2 scan mode. The spray voltage used for these positive and negative modes is 4000 and 35000 volts respectively. Sheath gas and auxiliary gas were set to 42 and 11 respectively. The mass scan range was 60-900 m/z, ACG (Automatic control gain) target at 100000 ions and maximum injection time was 50 ms for MS and ACG target was 20000 ions and maximum injection time 60 ms for MSMS was used. Data were processed using the IDSL.IPA software (https://cran.r-project.org/web/packages/IDSL.IPA/index.html) |
Ion Mode: | NEGATIVE |