Summary of Study ST002165
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001378. The data can be accessed directly via it's Project DOI: 10.21228/M8M12K This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002165 |
Study Title | Untargeted metabolomics profiling of mice urine after 5 Gy and 7.5 Gy total body radiation exposure at 24 hours - LCMS Study. |
Study Type | Untargeted LCMS |
Study Summary | Untargeted metabolomics profiling of mice urine after 5 Gy and 7.5 Gy total body radiation exposure at 24 hours. Metabolic profiling of urine samples were performed by TripleTOF 5600+ (AB Sciex) in both ionization mode |
Institute | Institute of Nuclear Medicine and Allied Sciences |
Department | Institute of Nuclear Medicine and Allied Sciences |
Laboratory | Metabolomics facility |
Last Name | Rana |
First Name | Poonam |
Address | DRDO, Lucknow Road, Timarpur |
poonamrana27@gmail.com | |
Phone | +911123905319 |
Submit Date | 2021-11-24 |
Num Groups | 3 |
Total Subjects | 21 |
Num Males | 21 |
Analysis Type Detail | LC-MS |
Release Date | 2022-05-31 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003547 | AN003548 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | ExionLC | ExionLC |
Column | Kinetex EVO C18 (100 x 2.1 mm,1.7um) | Kinetex EVO C18 (100 x 2.1 mm,1.7um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | ABI Sciex 5600 TripleTOF | ABI Sciex 5600 TripleTOF |
Ion Mode | POSITIVE | NEGATIVE |
Units | Intensity | Intensity |
MS:
MS ID: | MS003305 |
Analysis ID: | AN003547 |
Instrument Name: | ABI Sciex 5600 TripleTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Samples were ionized using Electron Spray Ionization(ESI) in both the modes. The various MS parameters used for the present study are as discussed. The gas flow, GS1 and GS2 were kept at 50 psi, curtain gas flow (CUR) at 30 psi and capillary voltage(ISVF) at 5500 V for positive and - 4500 V for negative ionization mode with source temperature 400 0C for both ionization modes. The MS calibration was performed through CDS (calibrant delivery system). For MS/MS fragmentation of metabolites, collision energy was set at 35 eV with a collision energy spread of ± 15 eV and declustering potential of 60 eV. Mass range was set at 100- 1200m/z. Metabolites were identified by matching with, company provided library and Metlin public database (https://metlin.scripps.edu). |
Ion Mode: | POSITIVE |
Acquisition Parameters File: | MS_Parameter.pdf |
MS ID: | MS003306 |
Analysis ID: | AN003548 |
Instrument Name: | ABI Sciex 5600 TripleTOF |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | Samples were ionized using Electron Spray Ionization(ESI) in both the modes. The various MS parameters used for the present study are as discussed. The gas flow, GS1 and GS2 were kept at 50 psi, curtain gas flow (CUR) at 30 psi and capillary voltage(ISVF) at 5500 V for positive and - 4500 V for negative ionization mode with source temperature 400 0C for both ionization modes. The MS calibration was performed through CDS (calibrant delivery system). For MS/MS fragmentation of metabolites, collision energy was set at 35 eV with a collision energy spread of ± 15 eV and declustering potential of 60 eV. Mass range was set at 100- 1200m/z. Metabolites were identified by matching with, company provided library and Metlin public database (https://metlin.scripps.edu). |
Ion Mode: | NEGATIVE |
Acquisition Parameters File: | MS_Parameter.pdf |