Summary of Study ST002385

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001535. The data can be accessed directly via it's Project DOI: 10.21228/M88T5J This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002385
Study TitleMetabolomics in small-spotted catshark reproduction- Seminal plasma Semi-polar
Study Summarythis study aimed to elucidate the influence of the environment (wild vs. aquarium) on the metabolic signatures in the seminal plasma (wild-captured vs. aquarium-housed).
Institute
Universidad CEU San Pablo
Last NameLorenzo Rebenaque
First NameLaura
AddressEd. Seminario. S/n, Moncada, Valencia, 46113, Spain
Emaillaura.lorenzorebenaque@uchceu.es
Phone615056012
Submit Date2022-11-27
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2022-12-30
Release Version1
Laura Lorenzo Rebenaque Laura Lorenzo Rebenaque
https://dx.doi.org/10.21228/M88T5J
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003885 AN003886
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Phenomenex Luna (100 x 2.1mm,2.5um) Phenomenex Luna (100 x 2.1mm,2.5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units m/z ratio m/z ratio

MS:

MS ID:MS003625
Analysis ID:AN003885
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:For the untargeted metabolomic analysis, Compound Discoverer software (Thermofisher Scientific) was used to identify the peaks, peak filtration, and peak alignment, and performed chromatogram alignment, peak picking, and public database (e.g., ChemSpider, KEGG, Metabolika) querying based on accurate masses (m/z).
Ion Mode:POSITIVE
  
MS ID:MS003626
Analysis ID:AN003886
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:For the untargeted metabolomic analysis, Compound Discoverer software (Thermofisher Scientific) was used to identify the peaks, peak filtration, and peak alignment, and performed chromatogram alignment, peak picking, and public database (e.g., ChemSpider, KEGG, Metabolika) querying based on accurate masses (m/z).
Ion Mode:NEGATIVE