Summary of Study ST002385
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001535. The data can be accessed directly via it's Project DOI: 10.21228/M88T5J This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002385 |
Study Title | Metabolomics in small-spotted catshark reproduction- Seminal plasma Semi-polar |
Study Summary | this study aimed to elucidate the influence of the environment (wild vs. aquarium) on the metabolic signatures in the seminal plasma (wild-captured vs. aquarium-housed). |
Institute | Universidad CEU San Pablo |
Last Name | Lorenzo Rebenaque |
First Name | Laura |
Address | Ed. Seminario. S/n, Moncada, Valencia, 46113, Spain |
laura.lorenzorebenaque@uchceu.es | |
Phone | 615056012 |
Submit Date | 2022-11-27 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2022-12-30 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003885 | AN003886 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | Phenomenex Luna (100 x 2.1mm,2.5um) | Phenomenex Luna (100 x 2.1mm,2.5um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | m/z ratio | m/z ratio |
MS:
MS ID: | MS003625 |
Analysis ID: | AN003885 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | For the untargeted metabolomic analysis, Compound Discoverer software (Thermofisher Scientific) was used to identify the peaks, peak filtration, and peak alignment, and performed chromatogram alignment, peak picking, and public database (e.g., ChemSpider, KEGG, Metabolika) querying based on accurate masses (m/z). |
Ion Mode: | POSITIVE |
MS ID: | MS003626 |
Analysis ID: | AN003886 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | For the untargeted metabolomic analysis, Compound Discoverer software (Thermofisher Scientific) was used to identify the peaks, peak filtration, and peak alignment, and performed chromatogram alignment, peak picking, and public database (e.g., ChemSpider, KEGG, Metabolika) querying based on accurate masses (m/z). |
Ion Mode: | NEGATIVE |