Summary of Study ST001173
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000785. The data can be accessed directly via it's Project DOI: 10.21228/M86T1D This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST001173 |
Study Title | Combinatorial metabolic mixtures for encoding abstract digital data |
Study Type | MALDI MS |
Study Summary | We present several kilobyte-scale image datasets stored in synthetic metabolomes, which are decoded with accuracy exceeding 98-99% using multi-mass logistic regression. |
Institute | Brown University |
Department | Engineering |
Laboratory | Rosenstein Lab |
Last Name | Kennedy |
First Name | Eamonn |
Address | Barus & Holley room 353, 184 Hope St |
eamonn_kennedy@brown.edu | |
Phone | 7737507192 |
Submit Date | 2019-04-19 |
Publications | E. Kennedy et al. “Encoding information in synthetic metabolomes” Plos One, accepted, 2019 |
Raw Data Available | Yes |
Raw Data File Type(s) | hdf5 |
Analysis Type Detail | MALDI-MS |
Release Date | 2019-05-15 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Project:
Project ID: | PR000785 |
Project DOI: | doi: 10.21228/M86T1D |
Project Title: | Combinatorial metabolic mixtures for encoding abstract digital data |
Project Type: | FTICR-MS acquisition of 1536-spot MALDI plates, comprising thousands of mixtures of common metabolites |
Project Summary: | This data comprises FT-ICR MS readouts of 1536-spot MALDI plates. Each spectra is a measure of a specific metabolic mixture from a library of 36 common metabolites. The combinatorial mixtures of metabolites are used to encode abstract digital data (images). A comprehensive list of the metabolites and specific mixture present in each spot on each plate are provided in metadata files. Data is provided in open-source .hdf5 files. |
Institute: | Brown University |
Department: | Engineering |
Laboratory: | Rosenstein Lab |
Last Name: | Kennedy |
First Name: | Eamonn |
Address: | Barus & Holley room 446, 184 Hope St |
Email: | eamonn_kennedy@brown.edu |
Phone: | 7737507192 |
Funding Source: | DARPA |
Publications: | E. Kennedy et al. “Encoding information in synthetic metabolomes” Plos One, accepted, 2019 |
Contributors: | Eamonn Kennedy, Christopher E. Arcadia, Joseph Geiser Peter M. Weber, Christopher Rose, Brenda M. Rubenstein and Jacob K. Rosenstein |
Subject:
Subject ID: | SU001239 |
Subject Type: | Synthetic |
Subject Species: | Escherichia coli |
Taxonomy ID: | 562 |
Factors:
Subject type: Synthetic; Subject species: Escherichia coli (Factor headings shown in green)
mb_sample_id | local_sample_id | Sample Type |
---|---|---|
SA081500 | e0114p03t02 | standard |
SA081501 | e0112p01t01 | standard |
SA081502 | e0117p01t01 | standard |
Showing results 1 to 3 of 3 |
Collection:
Collection ID: | CO001233 |
Collection Summary: | Extensive details of the collection parameters are provided in metadata .mat files (see in raw data zip file : README.pdf). Briefly, a Solarix 7T was used to collect FTICR MS data of thousands of MALDI spots comprised of synthetic metabolite mixtures. |
Collection Protocol ID: | NA |
Collection Protocol Filename: | There are multiple provided, e.g. please see : raw data zip file, e0114p03t02_instrument_settings.mat |
Sample Type: | Synthetic Mixture |
Collection Method: | FTICR MS |
Collection Location: | Brown University |
Collection Frequency: | 2000 |
Collection Duration: | shot_count: 500, 4x averaging, 1 second duration |
Volumeoramount Collected: | 0.1 nL |
Storage Conditions: | Room temperature |
Collection Vials: | 1 |
Storage Vials: | 36 |
Collection Tube Temp: | RT |
Additives: | Aminoacridine matrix |
Treatment:
Treatment ID: | TR001254 |
Treatment Summary: | Combinatorial mixtures of metabolites were deposited using a Labcyte Echo 550 on to a MALDI steel plate at 30-60 nL volumes. Aminoacridine matrix was added in the ratio 0.7:1 to 1:.7 to metabolite concentrations. The spot droplets were air dried. No further treatments were performed prior to data acquisition. |
Sample Preparation:
Sampleprep ID: | SP001247 |
Sampleprep Summary: | Combinatorial mixtures of metabolites were deposited using a Labcyte Echo 550 on to a MALDI steel plate at 30-60 nL volumes. Aminoacridine matrix was added in the ratio 0.7:1 to 1:.7 to metabolite concentrations. The spot droplets were air dried. No further preparations were performed prior to data acquisition. |
Combined analysis:
Analysis ID | AN001948 |
---|---|
Analysis type | MS |
Chromatography type | None (Direct infusion) |
Chromatography system | none |
Column | none |
MS Type | MALDI |
MS instrument type | FT-ICR |
MS instrument name | Bruker Solarix FT-ICR-MS |
Ion Mode | POSITIVE |
Units | mM |
Chromatography:
Chromatography ID: | CH001413 |
Instrument Name: | none |
Column Name: | none |
Chromatography Type: | None (Direct infusion) |
MS:
MS ID: | MS001804 |
Analysis ID: | AN001948 |
Instrument Name: | Bruker Solarix FT-ICR-MS |
Instrument Type: | FT-ICR |
MS Type: | MALDI |
MS Comments: | Extensive details of the data processing are provided in the readme.pdf file, and scripts for directly reading the data in Python are also provided. |
Ion Mode: | POSITIVE |