Summary of Study ST001231
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000824. The data can be accessed directly via it's Project DOI: 10.21228/M85Q5K This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001231 |
Study Title | Plasma untargeted metabolomics study of pulmonary tuberculosis |
Study Summary | In this study, differentially abundant plasma metabolites were screened by using the ultra-high performance liquid chromatography coupled with Q Exactive mass spectrometry in pulmonary tuberculosis(TB) patients and normal controls(NC) or patients with other pulmonary diseases such as, community-acquired pneumonia(CAP) and lung cancer(LC). |
Institute | Zhengjiang University |
Department | School of Medicine |
Laboratory | Institute of Cell Biology |
Last Name | Li |
First Name | Ji-Cheng |
Address | 866 Yuhangtang Road, West Lake District, Hangzhou, Zhejiang Province, 310058, PR China |
lijichen@zju.edu.cn | |
Phone | +86-571-88208088 |
Submit Date | 2019-08-05 |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2020-12-01 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Project:
Project ID: | PR000824 |
Project DOI: | doi: 10.21228/M85Q5K |
Project Title: | Pulmonary tuberculosis plasma untargeted metabolomics |
Project Type: | Untargeted MS analysis |
Project Summary: | An untargeted metabolomics study on plasma samples from human pulmonary tuberculosis |
Institute: | Zhengjiang University |
Department: | School of Medicine |
Laboratory: | Institute of Cell Biology |
Last Name: | Li |
First Name: | Ji-Cheng |
Address: | 866 Yuhangtang Road, West Lake District, Hangzhou, Zhejiang Province, 310058, PR China |
Email: | lijichen@zju.edu.cn |
Phone: | +86-571-88208088 |
Subject:
Subject ID: | SU001299 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Gender: | Male and female |
Species Group: | Mammals |
Factors:
Subject type: Human; Subject species: Homo sapiens (Factor headings shown in green)
mb_sample_id | local_sample_id | Disease |
---|---|---|
SA087726 | FY26 | CAP |
SA087727 | FY25 | CAP |
SA087728 | FY24 | CAP |
SA087729 | FY29 | CAP |
SA087730 | FY30 | CAP |
SA087731 | FY33 | CAP |
SA087732 | FY32 | CAP |
SA087733 | FY23 | CAP |
SA087734 | FY19 | CAP |
SA087735 | FY14 | CAP |
SA087736 | FY12 | CAP |
SA087737 | FY11 | CAP |
SA087738 | FY15 | CAP |
SA087739 | FY17 | CAP |
SA087740 | FY34 | CAP |
SA087741 | FY18 | CAP |
SA087742 | FY20 | CAP |
SA087743 | FY36 | CAP |
SA087744 | FY75 | CAP |
SA087745 | FY74 | CAP |
SA087746 | FY72 | CAP |
SA087747 | FY8 | CAP |
SA087748 | FY91 | CAP |
SA087749 | FY98 | CAP |
SA087750 | FY93 | CAP |
SA087751 | FY67 | CAP |
SA087752 | FY60 | CAP |
SA087753 | FY41 | CAP |
SA087754 | FY39 | CAP |
SA087755 | FY42 | CAP |
SA087756 | FY5 | CAP |
SA087757 | FY6 | CAP |
SA087758 | FY52 | CAP |
SA087759 | FY10 | CAP |
SA087760 | FY21 | CAP |
SA087761 | LC64 | LC |
SA087762 | LC42 | LC |
SA087763 | LC44 | LC |
SA087764 | LC41 | LC |
SA087765 | LC36 | LC |
SA087766 | LC28 | LC |
SA087767 | LC34 | LC |
SA087768 | LC46 | LC |
SA087769 | LC48 | LC |
SA087770 | LC63 | LC |
SA087771 | LC72 | LC |
SA087772 | LC61 | LC |
SA087773 | LC56 | LC |
SA087774 | LC53 | LC |
SA087775 | LC55 | LC |
SA087776 | LC23 | LC |
SA087777 | LC16 | LC |
SA087778 | LC92 | LC |
SA087779 | LC95 | LC |
SA087780 | LC91 | LC |
SA087781 | LC84 | LC |
SA087782 | LC74 | LC |
SA087783 | LC75 | LC |
SA087784 | LC69 | LC |
SA087785 | LC67 | LC |
SA087786 | LC05 | LC |
SA087787 | LC08 | LC |
SA087788 | LC14 | LC |
SA087789 | LC02 | LC |
SA087790 | LC01 | LC |
SA087791 | LC09 | LC |
SA087792 | N_02 | NC |
SA087793 | N_01 | NC |
SA087794 | N_36 | NC |
SA087795 | N_14 | NC |
SA087796 | N_13 | NC |
SA087797 | N_11 | NC |
SA087798 | N_15 | NC |
SA087799 | N_16 | NC |
SA087800 | N_18 | NC |
SA087801 | N_17 | NC |
SA087802 | N_10 | NC |
SA087803 | N_09 | NC |
SA087804 | N_04 | NC |
SA087805 | N_03 | NC |
SA087806 | N_05 | NC |
SA087807 | N_06 | NC |
SA087808 | N_08 | NC |
SA087809 | N_07 | NC |
SA087810 | N_19 | NC |
SA087811 | N_20 | NC |
SA087812 | N_31 | NC |
SA087813 | N_30 | NC |
SA087814 | N_32 | NC |
SA087815 | N_33 | NC |
SA087816 | N_35 | NC |
SA087817 | N_34 | NC |
SA087818 | N_29 | NC |
SA087819 | N_28 | NC |
SA087820 | N_23 | NC |
SA087821 | N_22 | NC |
SA087822 | N_24 | NC |
SA087823 | N_25 | NC |
SA087824 | N_27 | NC |
SA087825 | N_26 | NC |
Collection:
Collection ID: | CO001293 |
Collection Summary: | Morning fasting heparin anti-coagulated blood samples were drawn and centrifuged at 4°C, 3000 r / min for 10 min. The supernatant was aspirated, and frozen at -80°C. |
Sample Type: | Blood (plasma) |
Storage Conditions: | -80℃ |
Treatment:
Treatment ID: | TR001314 |
Treatment Summary: | No special treatment |
Sample Preparation:
Sampleprep ID: | SP001307 |
Sampleprep Summary: | The frozen heparin anti-coagulated plasma samples were thawed on ice and 100 μl of each sample was transferred to a 1.5ml sterile micro-centrifugen tube. After the addition of 300 μl of methanol (containing internal standard L-2-chlorophenylalanine 1 μg/ml), each sample was vortexed for 30 s, sonicated for 10 min in ice-water bath, and incubated for 1 h at -20°C to precipitate proteins. Then each sample was centrifuged at 12000 rpm for 15 min at 4°C. The resulting supernatants were transferred to LC-MS vials and stored at -80°C until the UPLC-QE-MS analysis. Each quality control sample was also prepared by mixing an equal aliquot of the supernatants from each sample. The treatment methods were the same as above. |
Combined analysis:
Analysis ID | AN002048 | AN002049 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Waters Acquity | Waters Acquity |
Column | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | NEGATIVE | POSITIVE |
Units | peak area | peak area |
Chromatography:
Chromatography ID: | CH001488 |
Chromatography Summary: | The mobile phase A was 0.1% formic acid in water for positive, and 5 mmol/L ammonium acetate in water for negative, and the mobile phase B was acetonitrile. The elution gradient was set as follows: 0 min, 1% B; 1 min, 1% B; 8 min, 99% B; 10 min, 99% B; 10.1 min, 1% B; 12 min, 1% B. |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
Flow Gradient: | 0 min, 1% B; 1 min, 1% B; 8 min, 99% B; 10 min, 99% B; 10.1 min, 1% B; 12 min, 1% B. |
Solvent A: | Pos mode:100% water; 0.1% formic acid, Neg mode:100% water; 5 mM ammonium acetate |
Solvent B: | 100% acetonitrile |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS001900 |
Analysis ID: | AN002048 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | mass range(m/z):70-1000 Convert the mass spectrometry raw data to the mzML format. Then do retention time correction, peak identification, peak extraction, peak integration, peak alignment, etc., and finally compare the database for material identification. ProteoWizard,XCMS,OSI-SMMS,in-house MS/MS database |
Ion Mode: | NEGATIVE |
MS ID: | MS001901 |
Analysis ID: | AN002049 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | mass range(m/z):70-1000 Convert the mass spectrometry raw data to the mzML format. Then do retention time correction, peak identification, peak extraction, peak integration, peak alignment, etc., and finally compare the database for material identification. ProteoWizard,XCMS,OSI-SMMS,in-house MS/MS database |
Ion Mode: | POSITIVE |