Summary of Study ST001890
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001190. The data can be accessed directly via it's Project DOI: 10.21228/M8WD84 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001890 |
Study Title | Multiomics Longitudinal Modeling of Preeclamptic Pregnancies (part II) |
Study Summary | Preeclampsia is a complex disease of pregnancy whose physiopathology remains unclear and that poses a threat to both mothers and infants. Specific complex changes in women's physiology precede a diagnosis of preeclampsia. Understanding multiple aspects of such a complex changes at different levels of biology can be enabled by simultaneous application of multiple assays. We developed prediction models for preeclampsia risk by analyzing six omics datasets from a longitudinal cohort of pregnant women. A machine learning-based multiomics model had high accuracy (area under the receiver operating characteristics curve (AUC) of 0.94, 95% confidence intervals (CI): [0.90, 0.99]). A prediction model using only ten urine metabolites provided an accuracy of the whole metabolomic dataset and was validated using an independent cohort of 16 women (AUC=0.87, 95% CI: [0.76, 0.99]). Integration with clinical variables further improved prediction accuracy of the urine metabolome model (AUC=0.90, 95% CI: [0.80, 0.99], urine metabolome, validated). We identified several biological pathways to be associated with preeclampsia. The findings derived from models were integrated with immune system cytometry data, confirming known physiological alterations associated with preeclampsia and suggesting novel associations between the immune and proteomic dynamics. While further validation in larger populations is necessary, these encouraging results will serve as a basis for a simple, early diagnostic test for preeclampsia. |
Institute | Stanford University |
Last Name | Contrepois |
First Name | Kevin |
Address | 300 Pasteur Dr |
kcontrep@stanford.edu | |
Phone | 6506664538 |
Submit Date | 2021-07-26 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2022-11-23 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Project:
Project ID: | PR001190 |
Project DOI: | doi: 10.21228/M8WD84 |
Project Title: | Preeclampsia and plasma metabolomics |
Project Summary: | Longitudinal untargeted plasma metabolomics of pregnant women with preeclampsia |
Institute: | Stanford University |
Last Name: | Contrepois |
First Name: | Kevin |
Address: | 300 Pasteur Dr |
Email: | kcontrep@stanford.edu |
Phone: | 6506664538 |
Subject:
Subject ID: | SU001968 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Factors:
Subject type: Human; Subject species: Homo sapiens (Factor headings shown in green)
mb_sample_id | local_sample_id | Gestational Age At Sampling | Gestational Age At Delivery | Preeclampsia |
---|---|---|---|---|
SA175644 | 1902405109 | 10 | 31 | 1 |
SA175645 | 1901705108 | 10 | 37 | 1 |
SA175646 | 1063405107 | 10 | 38 | 1 |
SA175647 | 1055805108 | 10 | 38 | 1 |
SA175648 | 1054105108 | 10 | 39 | - |
SA175649 | 1960005108 | 10 | 39 | 1 |
SA175650 | 1050205108 | 10 | 41 | - |
SA175651 | 1063905109 | 10 | 41 | 1 |
SA175652 | 1081605118 | 11 | 30 | 1 |
SA175653 | 1083605118 | 11 | 35 | 1 |
SA175654 | 1085105118 | 11 | 36 | 1 |
SA175655 | 1084905118 | 11 | 37 | 1 |
SA175656 | 1056105118 | 11 | 37 | 1 |
SA175657 | 1080905118 | 11 | 37 | 1 |
SA175658 | 1053505118 | 11 | 38 | - |
SA175659 | 1052805118 | 11 | 38 | - |
SA175660 | 1055105118 | 11 | 39 | - |
SA175661 | 1083305118 | 11 | 39 | 1 |
SA175662 | 1051505118 | 11 | 40 | - |
SA175663 | 1073205118 | 11 | 40 | - |
SA175664 | 1060105118 | 11 | 40 | 1 |
SA175665 | 1072205128 | 12 | 30 | 1 |
SA175666 | 1072705128 | 12 | 37 | 1 |
SA175667 | 1072105128 | 12 | 39 | - |
SA175668 | 1054705128 | 12 | 39 | - |
SA175669 | 1073305128 | 12 | 41 | - |
SA175670 | 1082205138 | 13 | 33 | 1 |
SA175671 | 1080305138 | 13 | 36 | 1 |
SA175672 | 1084005138 | 13 | 37 | 1 |
SA175673 | 1082405138 | 13 | 37 | 1 |
SA175674 | 1073605138 | 13 | 39 | 1 |
SA175675 | 1071205138 | 13 | 40 | - |
SA175676 | 1072305138 | 13 | 40 | 1 |
SA175677 | 1071305138 | 13 | 41 | - |
SA175678 | 1084905148 | 14 | 37 | 1 |
SA175679 | 1052405148 | 14 | 38 | - |
SA175680 | 1083305148 | 14 | 39 | 1 |
SA175681 | 1081605158 | 15 | 30 | 1 |
SA175682 | 1083605158 | 15 | 35 | 1 |
SA175683 | 1085105158 | 15 | 36 | 1 |
SA175684 | 1053005158 | 15 | 36 | 1 |
SA175685 | 1072705158 | 15 | 37 | 1 |
SA175686 | 1055805158 | 15 | 38 | 1 |
SA175687 | 1054105158 | 15 | 39 | - |
SA175688 | 1055105158 | 15 | 39 | - |
SA175689 | 1051505158 | 15 | 40 | - |
SA175690 | 1052305158 | 15 | 41 | - |
SA175691 | 1054605158 | 15 | 41 | - |
SA175692 | 1073305158 | 15 | 41 | - |
SA175693 | 1010405168 | 16 | 32 | 1 |
SA175694 | 1082205168 | 16 | 33 | 1 |
SA175695 | 1005605168 | 16 | 36 | 1 |
SA175696 | 1080905168 | 16 | 37 | 1 |
SA175697 | 1901705168 | 16 | 37 | 1 |
SA175698 | 1082405168 | 16 | 37 | 1 |
SA175699 | 1084005168 | 16 | 37 | 1 |
SA175700 | 1053505168 | 16 | 38 | - |
SA175701 | 1063405169 | 16 | 38 | 1 |
SA175702 | 1054705168 | 16 | 39 | - |
SA175703 | 1080405168 | 16 | 39 | - |
SA175704 | 1053805168 | 16 | 39 | - |
SA175705 | 1011205168 | 16 | 39 | 1 |
SA175706 | 1071205168 | 16 | 40 | - |
SA175707 | 1060105168 | 16 | 40 | 1 |
SA175708 | 1063905169 | 16 | 41 | 1 |
SA175709 | 1072205178 | 17 | 30 | 1 |
SA175710 | 1050505178 | 17 | 37 | - |
SA175711 | 1053305178 | 17 | 37 | 1 |
SA175712 | 1055305178 | 17 | 37 | 1 |
SA175713 | 1073605178 | 17 | 39 | 1 |
SA175714 | 1960005179 | 17 | 39 | 1 |
SA175715 | 1072305178 | 17 | 40 | 1 |
SA175716 | 1071305178 | 17 | 41 | - |
SA175717 | 1080305188 | 18 | 36 | 1 |
SA175718 | 1052405188 | 18 | 38 | - |
SA175719 | 1072105188 | 18 | 39 | - |
SA175720 | 1054805188 | 18 | 40 | - |
SA175721 | 1073205188 | 18 | 40 | - |
SA175722 | 1050305188 | 18 | 41 | - |
SA175723 | 1084905228 | 22 | 37 | 1 |
SA175724 | 1083305228 | 22 | 39 | 1 |
SA175725 | 1081605238 | 23 | 30 | 1 |
SA175726 | 1010405238 | 23 | 32 | 1 |
SA175727 | 1082405238 | 23 | 37 | 1 |
SA175728 | 1083605248 | 24 | 35 | 1 |
SA175729 | 1085105248 | 24 | 36 | 1 |
SA175730 | 1005605248 | 24 | 36 | 1 |
SA175731 | 1055305248 | 24 | 37 | 1 |
SA175732 | 1084005248 | 24 | 37 | 1 |
SA175733 | 1063405249 | 24 | 38 | 1 |
SA175734 | 1054705248 | 24 | 39 | - |
SA175735 | 1073205248 | 24 | 40 | - |
SA175736 | 1072205258 | 25 | 30 | 1 |
SA175737 | 1901705258 | 25 | 37 | 1 |
SA175738 | 1056105258 | 25 | 37 | 1 |
SA175739 | 1055805258 | 25 | 38 | 1 |
SA175740 | 1073605258 | 25 | 39 | 1 |
SA175741 | 1960005259 | 25 | 39 | 1 |
SA175742 | 1071205258 | 25 | 40 | - |
SA175743 | 1051505258 | 25 | 40 | - |
Collection:
Collection ID: | CO001961 |
Collection Summary: | Urine was collected from pregnant women |
Sample Type: | Urine |
Treatment:
Treatment ID: | TR001980 |
Treatment Summary: | N/A |
Sample Preparation:
Sampleprep ID: | SP001974 |
Sampleprep Summary: | Urine samples were thawed on ice, prepared and analyzed randomly as previously described (Contrepois et al., 2015). Briefly, urine samples were diluted 1:4 with 75% acetonitrile and 100% water for HILIC- and RPLC-MS experiments, respectively. Each sample was spiked-in with 15 analytical-grade IS. |
Combined analysis:
Analysis ID | AN003066 | AN003067 | AN003068 | AN003069 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | HILIC | Reversed phase | Reversed phase |
Chromatography system | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS |
Column | EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um) | EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um) | Agilent Zorbax SBaq (50 x 2.1mm,1.7um) | Agilent Zorbax SBaq (50 x 2.1mm,1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive HF hybrid Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | MS count | MS count | MS count | MS count |
Chromatography:
Chromatography ID: | CH002270 |
Chromatography Summary: | HILIC experiments were performed using a ZIC-HILIC column 2.1 x 100 mm, 3.5 μm, 200Å (Merck Millipore, Darmstadt, Germany) and mobile phase solvents consisting of 10 mM ammonium acetate in 50/50 acetonitrile/water (A) and 10 mM ammonium acetate in 95/5 acetonitrile/water (B). |
Instrument Name: | Thermo Dionex Ultimate 3000 RS |
Column Name: | EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um) |
Solvent A: | 50% acetonitrile/50% water; 10mM ammonium acetate |
Solvent B: | 95% acetonitrile/5% water; 10mM ammonium acetate |
Chromatography Type: | HILIC |
Chromatography ID: | CH002271 |
Chromatography Summary: | RPLC experiments were performed using a Zorbax SBaq column 2.1 x 50 mm, 1.7 μm, 100Å (Agilent Technologies, Palo Alto, CA) and mobile phase solvents consisting of 0.06% acetic acid in water (A) and 0.06% acetic acid in methanol (B). |
Instrument Name: | Thermo Dionex Ultimate 3000 RS |
Column Name: | Agilent Zorbax SBaq (50 x 2.1mm,1.7um) |
Solvent A: | 100% water; 0.06% acetic acid |
Solvent B: | 100% methanol; 0.06% acetic acid |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS002853 |
Analysis ID: | AN003066 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample. |
Ion Mode: | POSITIVE |
MS ID: | MS002854 |
Analysis ID: | AN003067 |
Instrument Name: | Thermo Q Exactive HF hybrid Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample. |
Ion Mode: | NEGATIVE |
MS ID: | MS002855 |
Analysis ID: | AN003068 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample. |
Ion Mode: | POSITIVE |
MS ID: | MS002856 |
Analysis ID: | AN003069 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample. |
Ion Mode: | NEGATIVE |