Summary of Study ST002397
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001544. The data can be accessed directly via it's Project DOI: 10.21228/M8440H This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002397 |
Study Title | System-level analysis of flux regulation of yeast show that glycolytic flux is controlled by allosteric regulation and enzyme phosphorylation |
Study Summary | Energy metabolism is central for cellular function and has therefore evolved to be tightly regulated such that energy production can be balanced to energy demand. Energy is being produced in the central carbon metabolism (CCM) and even though there has been extensive studies on how fluxes through the different pathways in this part of metabolism are regulated. There is little understanding of how fluxes are affected by posttranslational modifications and by allosteric regulators. Here we integrated multi-omics data (intracellular metabolome, extracellular metabolome, proteome, phosphoproteome, and fluxome) under 9 different chemostat conditions for building a mathematical model that could map functional regulatory events (FREs) in the Saccharomyces cerevisiae. Using hierarchical analysis combined with the mathematical model, we observed pathway and metabolism-specific flux regulation mechanisms in the CCM. We also found that the glycolytic flux increased with specific growth rate, and this increase was accompanied by a decrease of both metabolites derived FREs and protein phosphorylation level. |
Institute | Shanghai Center for Systems Biomedicine, Shanghai Jiaotong University |
Last Name | Chen |
First Name | Min |
Address | State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology |
mchen531@163.com | |
Phone | 18582480786 |
Submit Date | 2022-08-14 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | LC-MS |
Release Date | 2022-12-30 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Project:
Project ID: | PR001544 |
Project DOI: | doi: 10.21228/M8440H |
Project Title: | Quantify the absolute abundace of metabolite |
Project Summary: | Quantify the absolute abundace of metabolite of yeast under different specific growth rate. |
Institute: | Shanghai Center for Systems Biomedicine, Shanghai Jiaotong University |
Last Name: | Chen |
First Name: | Min |
Address: | State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology |
Email: | mchen531@163.com |
Phone: | 18582480786 |
Subject:
Subject ID: | SU002486 |
Subject Type: | Yeast |
Subject Species: | Saccharomyces cerevisiae |
Taxonomy ID: | 4932 |
Gender: | Not applicable |
Factors:
Subject type: Yeast; Subject species: Saccharomyces cerevisiae (Factor headings shown in green)
mb_sample_id | local_sample_id | Treatment |
---|---|---|
SA239031 | u0.027_pool1_PS | Control |
SA239032 | u0.355_pool1_PS | Glucose |
SA239033 | u0.385_pool1_PS | Glucose |
SA239034 | u0.316_pool1_PS | Glucose |
SA239035 | u0.207_pool1_PS | Glucose |
SA239036 | u0.051_pool1_PS | Glucose |
SA239037 | u0.118_pool1_PS | Glucose |
SA239038 | u0.154_pool1_PS | Glucose |
SA239039 | u0.249_pool1_PS | Glucose |
Showing results 1 to 9 of 9 |
Collection:
Collection ID: | CO002479 |
Collection Summary: | Cells were washed with cold PBS and them flash-frozen in liquid N2 |
Sample Type: | Yeast cells |
Storage Conditions: | -80℃ |
Treatment:
Treatment ID: | TR002498 |
Treatment Summary: | For quantification of intracellular metabolite concentrations,1.0 mL-broth samples were rapidly withdrawn and quenched in pre-weighed tubes containing 5 mL cold (−40 °C) pure methanol followed immediately by vigorous vortexing. The quenched samples were rapidly weighed and poured into a filtration device containing a cellulose membrane and previously layered with 15 mL of cold methanol (−40 °C). Subsequently, a vacuum was applied followed by an immediate additional washing step with 15 mL cold methanol (−40 °C). The filter containing the cold washed biomass was then transferred into a 50 mL-falcon tube containing 30 mL of preheated (75 °C) aqueous ethanol solution (75% v/v). 100 μL of 13C cell extract was added to the tube as an internal standard. The tube containing the sample was then tightly closed, shaken vigorously, and placed into a water bath at 95 °C during 3 min for metabolite extraction. The tubes were then cooled using an ice bath and the filter was removed. This extract was then concentrated by complete evaporation of the ethanol–water mixture under vacuum, and resuspended in 500 μL milliQ water. After a first centrifugation at 15000 g for 5 min at 1 °C, the supernatant was transferred into a centrifugal filter unit and centrifuged again at the same conditions. The filtrate was placed into a screw-capped polypropylene vial and stored at −80 °C until further analysis. Samples were analyzed by LC-MS. |
Sample Preparation:
Sampleprep ID: | SP002492 |
Sampleprep Summary: | Total liquids are divided into liquid phase vials. |
Processing Storage Conditions: | 4℃ |
Extract Storage: | On ice |
Combined analysis:
Analysis ID | AN003904 |
---|---|
Analysis type | MS |
Chromatography type | Reversed phase |
Chromatography system | Waters NanoAcquity |
Column | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) |
MS Type | ESI |
MS instrument type | Triple quadrupole |
MS instrument name | Thermo TSQ Quantum Ultra |
Ion Mode | NEGATIVE |
Units | umol/l |
Chromatography:
Chromatography ID: | CH002890 |
Instrument Name: | Waters NanoAcquity |
Column Name: | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) |
Column Temperature: | 40 |
Flow Rate: | 0.2ml/min |
Solvent A: | 100% water; 5 mM ammonium formate |
Solvent B: | 85% acetonitrile/15% water |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS003643 |
Analysis ID: | AN003904 |
Instrument Name: | Thermo TSQ Quantum Ultra |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Xcalibur |
Ion Mode: | NEGATIVE |