Summary of Study ST002713

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001681. The data can be accessed directly via it's Project DOI: 10.21228/M8DT5S This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002713
Study TitleRanolazine induced metabolic rewiring improves melanoma responses to targeted therapy and immunotherapy - lipidomics
Study SummaryLipidomics analysis was performed on A375 melanoma cells resistant to BRAF inhibitor vemurafenib (VR) and cells resistant to VR and treated with fatty acid oxidation inhibitor ranolazine.
Institute
University of Colorado Denver
Last NameHaines
First NameJulie
Address12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA
Emailjulie.haines@cuanschutz.edu
Phone3037243339
Submit Date2023-05-09
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2023-06-21
Release Version1
Julie Haines Julie Haines
https://dx.doi.org/10.21228/M8DT5S
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Project:

Project ID:PR001681
Project DOI:doi: 10.21228/M8DT5S
Project Title:Ranolazine induced metabolic rewiring improves melanoma responses to targeted therapy and immunotherapy
Project Summary:Metabolic rewiring affects resistance of melanoma to targeted- and immuno-therapy. We have found that increased fatty acid oxidation (FAO) during late stages of BRAF inhibitor (BRAFi) treatment enables the establishment of acquired resistance. Targeting FAO with ranolazine in vivo once acquired BRAFi-resistance emerges delays tumour recurrence. Single cell RNAseq analysis revealed that ranolazine diminishes the transcriptional NGFRhigh neural crest stem cell subpopulation, which is refractory against BRAFi and immunotherapy. Moreover, by rewiring the methionine salvage pathway, ranolazine enhanced melanoma immunogenicity through increased antigen presentation and interferon signalling. Combination of ranolazine with anti-PD-L1 antibodies strongly improved survival in mice, where it increased lymphocyte infiltration and enhanced anti-tumour responses. Altogether, we show that ranolazine increases the efficacy of targeted melanoma therapy through fatty acid and methionine salvage metabolic rewiring. Importantly, our study suggests that ranolazine could sensitize BRAFi-resistant tumours to immunotherapy, by modulating melanoma cell recognition and immune infiltration. Ranolazine is an FDA and EMA-approved anti-anginal drug with very mild side effects, and our preclinical data encourage its use as a therapeutic option to improve the two main therapeutic strategies currently used to treat metastatic melanoma.
Institute:University of Colorado Denver
Laboratory:Lab of Angelo D'Alessandro in collaboration with lab of Imanol Arozarena
Last Name:Haines
First Name:Julie
Address:12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA
Email:julie.haines@cuanschutz.edu
Phone:3037243339

Subject:

Subject ID:SU002818
Subject Type:Cultured cells
Subject Species:Homo sapiens
Gender:Female
Cell Biosource Or Supplier:ATCC
Cell Strain Details:A375
Species Group:Mammals

Factors:

Subject type: Cultured cells; Subject species: Homo sapiens (Factor headings shown in green)

mb_sample_id local_sample_id Treatment
SA273530A375P 4VEHICLE
SA273531A375P 3VEHICLE
SA273532A375P 1VEHICLE
SA273533A375P 2VEHICLE
SA273534A375 VR 4VEMURA
SA273535A375 VR 3VEMURA
SA273536A375 VR 2VEMURA
SA273537A375 VR 1VEMURA
SA273538A375 VR-Rano 4VEMURA+RANO
SA273539A375 VR-Rano 2VEMURA+RANO
SA273540A375 VR-Rano 1VEMURA+RANO
SA273541A375 VR-Rano 3VEMURA+RANO
Showing results 1 to 12 of 12

Collection:

Collection ID:CO002811
Collection Summary:All cell lines had been authenticated in 2021. Cells were expanded to generate enough vials from a single batch before the start of the study. Cell lines were cultured in Dulbecco’s Eagle’s Medium (DMEM) (cat#61965026, Gibco) supplemented with 10% fetal bovine serum (cat#10500064, Gibco) plus 1% penicillin/streptomycin (cat#15140122, Gibco). Cells were grown at 37°C in a 5% CO2 environment.
Sample Type:Melanoma cells

Treatment:

Treatment ID:TR002827
Treatment Summary:Melanoma cells seeded in 6-well plates were treated for 7 days with a high dose (5 or 10μM as indicated) of vemurafenib before switching to a lower concentration of the drug (0,5 or 1μM). Fresh medium and vemurafenib was added once weekly for further 3-4 weeks until arising colonies grew to confluence. Fatty Acid oxidation inhibitors ranolazine, etomoxir or thiroridazine were added once a week.

Sample Preparation:

Sampleprep ID:SP002824
Sampleprep Summary:Lipids from frozen cell pellets were extracted with cold methanol at a concentration of 2 million cells/mL. Samples were vortexed 30 min at 4 degrees C then supernatants clarified by centrifugation (10 min, 10,000 g, 4 degrees C) and transferred to autosampler vials.
Processing Storage Conditions:4℃
Extract Storage:-80℃

Combined analysis:

Analysis ID AN004397 AN004398
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (30 x 2.1mm,1.7um) Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE POSITIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH003299
Chromatography Summary:Negative C18
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-3 min 10-95% B at 0.3 mL/min, 3-4.2 min hold at 95% B at 0.3 mL/min, 4.2-4.3 min drop to 10% B at 0.45 mL/min, 4.3-4.9 min hold at 10%B while lowering flow rate to 0.4 mL/min, 4.9-5 min hold at 10%B while lowering flow rate to 0.3 mL/min.
Flow Rate:see gradient
Sample Injection:10 uL
Solvent A:75% water 25% acetonitrile 5 mM ammonium acetate
Solvent B:90% isopropanol 10% acetonitrile 5 mM ammonium acetate
Chromatography Type:Reversed phase
  
Chromatography ID:CH003300
Chromatography Summary:Positive C18
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (30 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-3 min 30-100% B at 0.3 mL/min, 3-4.2 min hold at 100% B at 0.3 mL/min, 4.2-4.3 min 100-30% B at 0.4 mL/min, 4.3-4.9 min hold at 30%B and 0.4 mL/min, 4.9-5 min hold at 30%B while lowering flow rate to 0.3 mL/min
Flow Rate:see gradient
Sample Injection:10 uL
Solvent A:75% water 25% acetonitrile 5 mM ammonium acetate
Solvent B:90% isopropanol 10% acetonitrile 5 mM ammonium acetate
Chromatography Type:Reversed phase

MS:

MS ID:MS004146
Analysis ID:AN004397
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q Exactive was run independently in positive and negative ion mode, scanning using full MS from 125-1500 m/z at 70,000 resolution and top 10 data-dependent MS2 at 17,500 resolution. Electrospray ionization was achieved with 45 Arb sheath gas, 25 Arb auxiliary gas, and 4 kV spray voltage. Calibration was performed prior to the run using the PierceTM Positive and Negative Ion Calibration Solutions (Thermo Fisher Scientific). Run order of samples was randomized and technical replicates were injected after every 4 samples to assess quality control.
Ion Mode:NEGATIVE
  
MS ID:MS004147
Analysis ID:AN004398
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q Exactive was run independently in positive and negative ion mode, scanning using full MS from 125-1500 m/z at 70,000 resolution and top 10 data-dependent MS2 at 17,500 resolution. Electrospray ionization was achieved with 45 Arb sheath gas, 25 Arb auxiliary gas, and 4 kV spray voltage. Calibration was performed prior to the run using the PierceTM Positive and Negative Ion Calibration Solutions (Thermo Fisher Scientific). Run order of samples was randomized and technical replicates were injected after every 4 samples to assess quality control.
Ion Mode:POSITIVE