Summary of Study ST002820

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001762. The data can be accessed directly via it's Project DOI: 10.21228/M8ZB1D This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files
Study IDST002820
Study TitleEvaluation of Novel Candidate Filtration Markers from a Global Metabolomics Discovery for Glomerular Filtration Rate Estimation (AASKG1)
Study SummaryBackground: Creatinine and cystatin-C are recommended for estimating glomerular filtration rate (eGFR) but accuracy is suboptimal. Using untargeted metabolomics data, we sought to identify candidate filtration markers using a novel approach based on their maximal joint association with measured GFR (mGFR) with flexibility to consider their biological and chemical properties later. Methods: We analyzed metabolites measured in seven diverse studies of 2,851 participants on the Metabolon H4 platform that had Pearson correlations with log mGFR <-0.5. We used a stepwise approach to develop models to estimate mGFR including two to 15 metabolites with and without inclusion of creatinine and demographics. We then selected candidate filtration markers from those metabolites found >20% in models that did not demonstrate substantial overfitting in cross-validation and with small (<0.1 in absolute value) coefficients for demographics. Results: In total, 456 named metabolites were present in all studies, and 36 had correlations <-0.5 with mGFR. We developed 2,225 models including these metabolites; all had lower RMSEs and smaller coefficients for demographic variables compared to estimates using untargeted creatinine. Cross-validated RMSEs (0.187-0.213) were similar to original RMSEs for models with ≤ 10 metabolites. Our criteria identified 17 metabolites, including 12 new candidate filtration markers. Conclusion: We identified candidate metabolites with maximal joint association with mGFR and minimal association with demographic variables across varied clinical settings. Future analyses will assess metabolite biological and chemical characteristics in the path towards development of a panel eGFR that is more accurate and less reliant on demographic variables than current eGFR. ACRONYMS AASKG1: African American Study of Kidney (patient data at G1 visit). ALTOLD: Assessing Long Term Outcomes in Living Kidney Donors study. MDRD: The Modification of Diet in Renal Disease study.
Institute
Tufts Medical Center
DepartmentNephrology
Last NameInker
First NameLesley
Address800 Washington Street
EmailLesley.Inker@tuftsmedicine.org
Phone6176368783
Submit Date2023-08-17
Analysis Type DetailOther
Release Date2023-09-06
Release Version1
Lesley Inker Lesley Inker
https://dx.doi.org/10.21228/M8ZB1D
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Project:

Project ID:PR001762
Project DOI:doi: 10.21228/M8ZB1D
Project Title:Improving kidney function assessment in health and disease
Project Summary:Use results from a global metabolomics platform with existing measured GFR assessments to identify a set of markers from which to develop a highly accurate targeted mass spectrometry multiplex assay
Institute:Tufts Medical Center
Department:Nephrology
Laboratory:Metabolon; University of Minnesota
Last Name:Inker
First Name:Lesley
Address:800 Washington Street, Boston, Massachusetts, 02111, USA
Email:Lesley.Inker@tuftsmedicine.org
Phone:6176368783
Funding Source:NIDDK

Subject:

Subject ID:SU002929
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:18 and older
Gender:Male and female

Factors:

Subject type: Human; Subject species: Homo sapiens (Factor headings shown in green)

mb_sample_id local_sample_id study
SA3036823900716AASKG1
SA3036833900715AASKG1
SA3036843900717AASKG1
SA3036853900719AASKG1
SA3036863900720AASKG1
SA3036873900713AASKG1
SA3036883900718AASKG1
SA3036893900711AASKG1
SA3036903900707AASKG1
SA3036913900706AASKG1
SA3036923900708AASKG1
SA3036933900709AASKG1
SA3036943900721AASKG1
SA3036953900710AASKG1
SA3036963900712AASKG1
SA3036973900723AASKG1
SA3036983900732AASKG1
SA3036993900731AASKG1
SA3037003900733AASKG1
SA3037013900734AASKG1
SA3037023900736AASKG1
SA3037033900735AASKG1
SA3037043900730AASKG1
SA3037053900729AASKG1
SA3037063900724AASKG1
SA3037073900705AASKG1
SA3037083900725AASKG1
SA3037093900726AASKG1
SA3037103900728AASKG1
SA3037113900727AASKG1
SA3037123900722AASKG1
SA3037133900704AASKG1
SA3037143900684AASKG1
SA3037153900683AASKG1
SA3037163900685AASKG1
SA3037173900686AASKG1
SA3037183900688AASKG1
SA3037193900687AASKG1
SA3037203900682AASKG1
SA3037213900681AASKG1
SA3037223900676AASKG1
SA3037233900675AASKG1
SA3037243900677AASKG1
SA3037253900678AASKG1
SA3037263900680AASKG1
SA3037273900679AASKG1
SA3037283900689AASKG1
SA3037293900690AASKG1
SA3037303900699AASKG1
SA3037313900698AASKG1
SA3037323900700AASKG1
SA3037333900701AASKG1
SA3037343900703AASKG1
SA3037353900702AASKG1
SA3037363900697AASKG1
SA3037373900696AASKG1
SA3037383900692AASKG1
SA3037393900691AASKG1
SA3037403900693AASKG1
SA3037413900694AASKG1
SA3037423900695AASKG1
SA3037433900737AASKG1
SA3037443900739AASKG1
SA3037453900780AASKG1
SA3037463900779AASKG1
SA3037473900781AASKG1
SA3037483900782AASKG1
SA3037493900784AASKG1
SA3037503900783AASKG1
SA3037513900778AASKG1
SA3037523900777AASKG1
SA3037533900772AASKG1
SA3037543900771AASKG1
SA3037553900773AASKG1
SA3037563900774AASKG1
SA3037573900776AASKG1
SA3037583900775AASKG1
SA3037593900785AASKG1
SA3037603900786AASKG1
SA3037613900797AASKG1
SA3037623900796AASKG1
SA3037633900798AASKG1
SA3037643900799AASKG1
SA3037653900801AASKG1
SA3037663900800AASKG1
SA3037673900795AASKG1
SA3037683900794AASKG1
SA3037693900788AASKG1
SA3037703900787AASKG1
SA3037713900789AASKG1
SA3037723900790AASKG1
SA3037733900793AASKG1
SA3037743900792AASKG1
SA3037753900770AASKG1
SA3037763900769AASKG1
SA3037773900749AASKG1
SA3037783900748AASKG1
SA3037793900750AASKG1
SA3037803900751AASKG1
SA3037813900753AASKG1
Showing page 1 of 11     Results:    1  2  3  4  5  Next  Last     Showing results 1 to 100 of 1002

Collection:

Collection ID:CO002922
Collection Summary:samples were obtained from NIDDK repository
Sample Type:Blood (plasma)

Treatment:

Treatment ID:TR002938
Treatment Summary:Samples were prepared using the automated MicroLab STAR® system from Hamilton Company. Several recovery standards were added prior to the first step in the extraction process for QC purposes. To remove protein, dissociate small molecules bound to protein or trapped in the precipitated protein matrix, and to recover chemically diverse metabolites, proteins were precipitated with methanol under vigorous shaking for 2 min (Glen Mills GenoGrinder 2000) followed by centrifugation. The resulting extract was divided into five fractions: two for analysis by two separate reverse phase (RP)/UPLC-MS/MS methods with positive ion mode electrospray ionization (ESI), one for analysis by RP/UPLC-MS/MS with negative ion mode ESI, one for analysis by HILIC/UPLC-MS/MS with negative ion mode ESI, and one sample was reserved for backup. Samples were placed briefly on a TurboVap® (Zymark) to remove the organic solvent. The sample extracts were stored overnight under nitrogen before preparation for analysis.

Sample Preparation:

Sampleprep ID:SP002935
Sampleprep Summary:All methods utilized a Waters ACQUITY ultra-performance liquid chromatography (UPLC) and a Thermo Scientific Q-Exactive high resolution/accurate mass spectrometer interfaced with a heated electrospray ionization (HESI-II) source and Orbitrap mass analyzer operated at 35,000 mass resolution. The sample extract was dried then reconstituted in solvents compatible to each of the four methods. Each reconstitution solvent contained a series of standards at fixed concentrations to ensure injection and chromatographic consistency. One aliquot was analyzed using acidic positive ion conditions, chromatographically optimized for more hydrophilic compounds. In this method, the extract was gradient eluted from a C18 column (Waters UPLC BEH C18-2.1x100 mm, 1.7 µm) using water and methanol, containing 0.05% perfluoropentanoic acid (PFPA) and 0.1% formic acid (FA). Another aliquot was also analyzed using acidic positive ion conditions, however it was chromatographically optimized for more hydrophobic compounds. In this method, the extract was gradient eluted from the same afore mentioned C18 column using methanol, acetonitrile, water, 0.05% PFPA and 0.01% FA and was operated at an overall higher organic content. Another aliquot was analyzed using basic negative ion optimized conditions using a separate dedicated C18 column. The basic extracts were gradient eluted from the column using methanol and water, however with 6.5mM Ammonium Bicarbonate at pH 8. The fourth aliquot was analyzed via negative ionization following elution from a HILIC column (Waters UPLC BEH Amide 2.1x150 mm, 1.7 µm) using a gradient consisting of water and acetonitrile with 10mM Ammonium Formate, pH 10.8. The MS analysis alternated between MS and data-dependent MSn scans using dynamic exclusion. The scan range varied slighted between methods but covered 70-1000 m/z. Raw data files are archived and extracted as described below

Combined analysis:

Analysis ID AN004594 AN004595 AN004596 AN004597
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase HILIC
Chromatography system Waters Acquity Waters Acquity Waters Acquity Waters Acquity
Column Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units raw area counts rescaled to set the median equal to 1 raw area counts rescaled to set the median equal to 1 raw area counts rescaled to set the median equal to 1 raw area counts rescaled to set the median equal to 1

Chromatography:

Chromatography ID:CH003454
Chromatography Summary:Low pH polar (LC/MS Pos early)
Instrument Name:Waters Acquity
Column Name:Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
Column Temperature:-
Flow Gradient:-
Flow Rate:-
Solvent A:-
Solvent B:-
Chromatography Type:Reversed phase
  
Chromatography ID:CH003455
Chromatography Summary:Low pH Lipophilic (LC/MS Pos late)
Instrument Name:Waters Acquity
Column Name:Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
Column Temperature:-
Flow Gradient:-
Flow Rate:-
Solvent A:-
Solvent B:-
Chromatography Type:Reversed phase
  
Chromatography ID:CH003456
Chromatography Summary:High pH (LC/MS Neg)
Instrument Name:Waters Acquity
Column Name:Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
Column Temperature:-
Flow Gradient:-
Flow Rate:-
Solvent A:-
Solvent B:-
Chromatography Type:Reversed phase
  
Chromatography ID:CH003457
Chromatography Summary:HILIC (LC/MS Polar Neg)
Instrument Name:Waters Acquity
Column Name:Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um)
Column Temperature:-
Flow Gradient:-
Flow Rate:-
Solvent A:-
Solvent B:-
Chromatography Type:HILIC

MS:

MS ID:MS004340
Analysis ID:AN004594
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Pos early)
Ion Mode:POSITIVE
  
MS ID:MS004341
Analysis ID:AN004595
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Pos late)
Ion Mode:POSITIVE
  
MS ID:MS004342
Analysis ID:AN004596
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Neg)
Ion Mode:NEGATIVE
  
MS ID:MS004343
Analysis ID:AN004597
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolon (LC/MS Polar)
Ion Mode:NEGATIVE
  logo