MoNA MS database records for ( )-Catechin
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
VF-NPL-QEHF013285 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013286 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013287 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013288 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013289 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013290 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013945 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013946 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013947 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013948 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013949 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013950 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002066 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002067 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002068 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002069 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002070 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002071 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
HMDB0002780_ms_ms_285568 | Agilent 6530 Q-TOF | ESI-TOF | - | - | - | negative | - |
HMDB0002780_ms_ms_285569 | Agilent 6530 Q-TOF | ESI-TOF | - | - | - | negative | - |
HMDB0002780_ms_ms_285570 | Agilent 6530 Q-TOF | ESI-TOF | - | - | - | negative | - |
HMDB0002780_ms_ms_285571 | Agilent 6530 Q-TOF | ESI-TOF | - | - | - | negative | - |
HMDB0037953_ms_ms_285568 | Agilent 6530 Q-TOF | ESI-TOF | - | - | - | negative | - |
HMDB0037953_ms_ms_285569 | Agilent 6530 Q-TOF | ESI-TOF | - | - | - | negative | - |
HMDB0037953_ms_ms_285570 | Agilent 6530 Q-TOF | ESI-TOF | - | - | - | negative | - |
HMDB0037953_ms_ms_285571 | Agilent 6530 Q-TOF | ESI-TOF | - | - | - | negative | - |
PS045501 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS045502 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS045503 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS045504 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS045507 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS045508 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
FiehnLib000482 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0002780_c_ms_101915 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0002780_c_ms_101916 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0002780_c_ms_99783 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0037953_c_ms_101915 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0037953_c_ms_101916 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0037953_c_ms_99783 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
MoNA037720 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038470 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
BML00630 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
FiehnHILIC001819 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC002631 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
MoNA033684 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA033685 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA033686 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA034845 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034846 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA034847 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA035265 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA035266 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA035267 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA035845 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA035846 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA035847 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
PB001329 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB001330 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB001331 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
PB001332 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 55 eV | [M+H]+ | positive | MS2 |
PB002429 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M-H]- | negative | MS2 |
PB002430 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M-H]- | negative | MS2 |
PB002431 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
PB002432 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 55 eV | [M-H]- | negative | MS2 |
PR100262 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100687 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
RIKENPlaSMA002549 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002555 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002561 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002567 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002573 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002579 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002585 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002591 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002597 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002603 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002609 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002615 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA006214 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006226 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006262 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006268 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RP017801 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP017802 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP017803 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
RP017811 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
RP017812 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
RP017813 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF003396 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003397 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003398 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003399 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003400 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003401 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003420 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003421 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003422 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003423 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003424 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003425 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007092 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007093 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007094 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007095 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007096 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007097 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
MetaboBASE0014 | impact HD | LC-ESI-TOF | ESI | 10 | - | negative | - |
MetaboBASE0015 | impact HD | LC-ESI-TOF | ESI | 20 | [M-H]- | negative | MS2 |
MetaboBASE0016 | impact HD | LC-ESI-TOF | ESI | - | - | negative | - |
MetaboBASE0017 | impact HD | LC-ESI-TOF | ESI | 26.25 | [M-H]- | negative | MS2 |
PT104550 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT204550 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
VF-NPL-LTQ003688 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ003689 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ003690 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ007145 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ007146 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
PM003721 | XCT | QIT | ESI | 100% | [M-H]- | negative | MS2 |
PM003722 | XCT | QIT | ESI | 100% | [M+H]+ | positive | MS2 |
PM003725 | XCT | QIT | ESI | 100% | [M+H]+ | positive | MS2 |
PM016405 | MSD 1100 | QIT | ESI | 20% | [M+H]+ | positive | MS2 |
PM017701 | LTQ | QIT | ESI | 35% | [M+H]+ | positive | MS2 |
PM000403 | API 3000 | QqQ | ESI | -20 | [M-H]- | negative | MS2 |
PM012532 | API QSTAR | Q-TOF | ESI | 20->80V | [M-H]- | negative | MS2 |
HMDB0002780_ms_ms_2128 | API QSTAR | Quattro_QQQ | - | - | - | negative | - |
HMDB0002780_ms_ms_2129 | API QSTAR | Quattro_QQQ | - | - | - | negative | - |
HMDB0002780_ms_ms_2130 | API QSTAR | Quattro_QQQ | - | - | - | negative | - |
HMDB0037953_ms_ms_2128 | API QSTAR | Quattro_QQQ | - | - | - | negative | - |
HMDB0037953_ms_ms_2129 | API QSTAR | Quattro_QQQ | - | - | - | negative | - |
HMDB0037953_ms_ms_2130 | API QSTAR | Quattro_QQQ | - | - | - | negative | - |
CCMSLIB00000081476 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000081477 | qTof | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00000081478 | qTof | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000579277 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000848301 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00004681472 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00004684181 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00004684245 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |