MoNA MS database records for Cortisone
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
CB000366 | ABSciex API3200 LC/MS system | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS1 |
FiehnLib001002 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
WA000374 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA000375 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA000376 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA000377 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA000378 | ZQ, Waters | LC-ESI-Q | ESI | - | - | positive | MS1 |
WA000385 | ZQ, Waters | LC-ESI-Q | ESI | - | - | negative | MS1 |
WA000386 | ZQ, Waters | LC-ESI-Q | ESI | - | - | negative | MS1 |
WA000387 | ZQ, Waters | LC-ESI-Q | ESI | - | - | negative | MS1 |
WA000388 | ZQ, Waters | LC-ESI-Q | ESI | - | - | negative | MS1 |
WA000389 | ZQ, Waters | LC-ESI-Q | ESI | - | - | negative | MS1 |
WA000390 | ZQ, Waters | LC-ESI-Q | ESI | - | - | negative | MS1 |
AU239301 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
AU239302 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
AU239303 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
AU239304 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
AU239305 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
AU239306 | Bruker maXis Impact | LC-ESI-QTOF | ESI | Ramp 22.8-34.2 eV | [M+H]+ | positive | MS2 |
AU239357 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
AU239358 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
AU239359 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
AU239360 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
CCMSLIB00000077194 | Q-TOF | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000079047 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000085485 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005463901 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005463902 | Orbitrap | - | - | - | [2M+Na]+ | positive | MS2 |
CCMSLIB00005463903 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005720592 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720898 | qTof | - | - | - | [M-H]- | negative | MS2 |
EQ319901 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 15 (nominal) | [M+H]+ | positive | MS2 |
EQ319902 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 30 (nominal) | [M+H]+ | positive | MS2 |
EQ319903 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 45 (nominal) | [M+H]+ | positive | MS2 |
EQ319904 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 60 (nominal) | [M+H]+ | positive | MS2 |
EQ319905 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 75 (nominal) | [M+H]+ | positive | MS2 |
EQ319906 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 90 (nominal) | [M+H]+ | positive | MS2 |
EQ319907 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 120 (nominal) | [M+H]+ | positive | MS2 |
EQ319908 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 150 (nominal) | [M+H]+ | positive | MS2 |
EQ319909 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 180 (nominal) | [M+H]+ | positive | MS2 |
EQ319951 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 15 (nominal) | [M-H]- | negative | MS2 |
EQ319952 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 30 (nominal) | [M-H]- | negative | MS2 |
EQ319953 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 45 (nominal) | [M-H]- | negative | MS2 |
EQ319954 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 60 (nominal) | [M-H]- | negative | MS2 |
EQ319955 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 75 (nominal) | [M-H]- | negative | MS2 |
EQ319956 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 90 (nominal) | [M-H]- | negative | MS2 |
EQ319957 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 120 (nominal) | [M-H]- | negative | MS2 |
EQ319958 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 150 (nominal) | [M-H]- | negative | MS2 |
EQ319959 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 180 (nominal) | [M-H]- | negative | MS2 |
FiehnHILIC000277 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001130 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC001850 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC002650 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
LU112001 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M+H]+ | positive | MS2 |
LU112002 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M+H]+ | positive | MS2 |
LU112003 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M+H]+ | positive | MS2 |
LU112004 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M+H]+ | positive | MS2 |
LU112006 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M+H]+ | positive | MS2 |
LU112051 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 15 | [M-H]- | negative | MS2 |
LU112052 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 30 | [M-H]- | negative | MS2 |
LU112053 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 45 | [M-H]- | negative | MS2 |
LU112054 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 60 | [M-H]- | negative | MS2 |
LU112055 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 75 | [M-H]- | negative | MS2 |
LU112056 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | ESI | 90 | [M-H]- | negative | MS2 |
MoNA018191 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA018192 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
MoNA018193 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M-H]- | negative | MS2 |
MoNA018194 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M-H]- | negative | MS2 |
MoNA018466 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA018467 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA018468 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA018469 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA018470 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA018471 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA032561 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032566 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032567 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA034692 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034695 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034699 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA036396 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036397 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036401 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA037355 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038106 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038691 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
NA000001 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 10 % (nominal) | [M+H]+ | positive | MS2 |
NA000002 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
NA000003 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 20 % (nominal) | [M+H]+ | positive | MS2 |
NA000004 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 25 % (nominal) | [M+H]+ | positive | MS2 |
NA000005 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
NA000006 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 40 % (nominal) | [M+H]+ | positive | MS2 |
NA000007 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
NA000008 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 50 % (nominal) | [M+H]+ | positive | MS2 |
NA000009 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
NA000010 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
NA000011 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 70 % (nominal) | [M+H]+ | positive | MS2 |
NA000012 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 % (nominal) | [M+H]+ | positive | MS2 |
NA000013 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 % (nominal) | [M+H]+ | positive | MS2 |
NA000014 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 65 % (nominal) | [M+H]+ | positive | MS2 |
NA000015 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
NA000016 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 100 % (nominal) | [M+H]+ | positive | MS2 |
NA000017 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
NA000018 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 110 % (nominal) | [M+H]+ | positive | MS2 |
NA000019 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 85 % (nominal) | [M+H]+ | positive | MS2 |
NA000020 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 120 % (nominal) | [M+H]+ | positive | MS2 |
NA000021 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 130 % (nominal) | [M+H]+ | positive | MS2 |
NA000022 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 95 % (nominal) | [M+H]+ | positive | MS2 |
NA000023 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 140 % (nominal) | [M+H]+ | positive | MS2 |
NA000024 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 105 % (nominal) | [M+H]+ | positive | MS2 |
NA000025 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 150 % (nominal) | [M+H]+ | positive | MS2 |
NGA00753 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA00754 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA00755 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
NGA00756 | Agilent 6410 Triple Quadrupole... | LC-ESI-QQQ | - | - | [M+H]+ | positive | MS2 |
UF415401 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF415402 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF415403 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF415404 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF423101 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
UF423102 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 (nominal) | [M+H]+ | positive | MS2 |
UF423103 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 (nominal) | [M+H]+ | positive | MS2 |
UF423104 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 (nominal) | [M+H]+ | positive | MS2 |
VF-NPL-LTQ007121 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ007123 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-QEHF000526 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000527 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000528 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000529 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000530 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000531 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013894 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013895 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013896 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013897 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013898 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013899 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002105 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002106 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002107 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002108 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002109 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002110 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003470 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003471 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003472 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003473 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003474 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003475 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007147 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF007148 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF007149 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF007150 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF007151 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF007152 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF007153 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007154 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007155 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007156 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007157 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF007158 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-LTQ007122 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS3 Composite |
VF-NPL-LTQ000254 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-LTQ007124 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
BAF_UVA_POS000550 | Thermo Finnigan LTQ | - | - | - | - | - | - |
BAF_UVA_POS000551 | Thermo Finnigan LTQ | - | - | - | - | - | - |
BAF_UVA_POS000552 | Thermo Finnigan LTQ | - | - | - | - | - | - |
HMDB0002802_c_ms_99784 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0002802_ms_ms_2134 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0002802_ms_ms_2135 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
HMDB0002802_ms_ms_2136 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
MoNA016677 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
MoNA016855 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+Na]+ | positive | - |
MoNA041691 | Agilent 6560 | - | - | 20 | [M+H]+ | positive | - |
MoNA041751 | Agilent 6560 | - | - | 40 | [M+H]+ | positive | - |