MoNA MS database records for Deoxyadenosine monophosphate
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA001687 | - | Electrospray Ionization (ESI) | - | - | positive | MS2 | |
PT201420 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT101423 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | 30 V | [M+H]+ | positive | MS2 |
PT101420 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
MoNA024268 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
PS014207 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS014208 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PS014201 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS014202 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS014203 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS014204 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS014205 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PS014206 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M+H]+ | positive | MS2 |
PR100521 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR100084 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 30 V | [M+H]+ | positive | MS2 |
PR100083 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
BML80251 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML80250 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
MoNA034739 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034740 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034743 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA033642 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036431 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA033647 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA036429 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA033644 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA036428 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA002297 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA002294 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA002295 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
FiehnLib000198 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00005464538 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005464504 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464505 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
PR010127 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00000578148 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000577915 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720358 | qTof | - | - | - | [M+H]+ | positive | MS2 |
FiehnHILIC001630 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC000891 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038123 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC000019 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037372 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038702 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
EMBL-MCF_spec29219 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec104275 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
MoNA016689 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
HMDB0000905_ms_ms_1289 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000905_ms_ms_1290 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000905_ms_ms_1291 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
BAF_UVA_POS000160 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000161 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000878 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000879 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000880 | XEVO-G2S | - | - | - | - | - | - |