MoNA MS database records for Deoxyadenosine monophosphate

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
MoNA001687-Electrospray Ionization (ESI)--positiveMS2
PT201420Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M-H]-negativeMS2
PT101423Q-Tof Premier, WatersLC-Q-TOF/MSESI30 V[M+H]+positiveMS2
PT101420Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M+H]+positiveMS2
MoNA024268Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M-H]-negativeMS2
PS014207TQD, WatersFlow-injection QqQ/MSESI10[M-H]-negativeMS2
PS014208TQD, WatersFlow-injection QqQ/MSESI20[M-H]-negativeMS2
PS014201TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS014202TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PS014203TQD, WatersFlow-injection QqQ/MSESI30[M+H]+positiveMS2
PS014204TQD, WatersFlow-injection QqQ/MSESI40[M+H]+positiveMS2
PS014205TQD, WatersFlow-injection QqQ/MSESI50[M+H]+positiveMS2
PS014206TQD, WatersFlow-injection QqQ/MSESI60[M+H]+positiveMS2
PR100521UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR100084UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI30 V[M+H]+positiveMS2
PR100083UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
BML80251Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF---negativeMS1
BML80250Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF---positiveMS1
MoNA034739Agilent qTOF 6545LC-ESI-QTOF-10 eV[M-H]-negativeMS2
MoNA034740Agilent qTOF 6545LC-ESI-QTOF-20 eV[M-H]-negativeMS2
MoNA034743Agilent qTOF 6545LC-ESI-QTOF-40 eV[M-H]-negativeMS2
MoNA033642Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA036431Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA033647Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA036429Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA033644Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
MoNA036428Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
MoNA002297Agilent QTOF 6550LC-ESI-QTOF-10[M+H]+positiveMS2
MoNA002294Agilent QTOF 6550LC-ESI-QTOF-20[M+H]+positiveMS2
MoNA002295Agilent QTOF 6550LC-ESI-QTOF-40[M+H]+positiveMS2
FiehnLib000198Leco Pegasus IVGC-EI-TOF---positiveMS1
CCMSLIB00005464538Orbitrap---[M-H]-negativeMS2
CCMSLIB00005464504Orbitrap---[M+H]+positiveMS2
CCMSLIB00005464505Orbitrap---[M+Na]+positiveMS2
PR010127Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
CCMSLIB00000578148Q-Exactive Plus---[M-H]-negativeMS2
CCMSLIB00000577915Q-Exactive Plus---[M+H]+positiveMS2
CCMSLIB00005720358qTof---[M+H]+positiveMS2
FiehnHILIC001630SCIEX TripleTOF 6600LC-ESI-QTOF-35 eV[M+H]+positiveMS2
FiehnHILIC000891Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
MoNA038123Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
FiehnHILIC000019Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA037372Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA038702Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
EMBL-MCF_spec29219Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M-H]-negativeMS2
EMBL-MCF_spec104275Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M+H]+positiveMS2
MoNA016689XEVO-G2SLC-ESI-QTOF-6V (MS1); Ramp 15V-30V (MSE)[M+H]+positive-
HMDB0000905_ms_ms_1289XEVO-G2SQuattro_QQQ---positive-
HMDB0000905_ms_ms_1290XEVO-G2SQuattro_QQQ---positive-
HMDB0000905_ms_ms_1291XEVO-G2SQuattro_QQQ---positive-
BAF_UVA_POS000160XEVO-G2S------
BAF_UVA_POS000161XEVO-G2S------
BAF_UVA_POS000878XEVO-G2S------
BAF_UVA_POS000879XEVO-G2S------
BAF_UVA_POS000880XEVO-G2S------
  logo