MoNA MS database records for Galactose 1-phosphate
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PT203760 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT212330 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
MoNA024085 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA024130 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
PS037607 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS123307 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS037608 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PS123308 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PS037609 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M-H]- | negative | MS2 |
PS037610 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M-H]- | negative | MS2 |
PS123310 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M-H]- | negative | MS2 |
PS037611 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M-H]- | negative | MS2 |
PS037601 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS123301 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS123306 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M+H]+ | positive | MS2 |
PR100627 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR100929 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
MoNA033995 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA033984 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA033988 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
CCMSLIB00005464422 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000578219 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
MoNA037859 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA037147 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
HMDB0000645_ms_ms_1657 | Thermo Q Exactive HF | Quattro_QQQ | - | - | - | negative | MS2 |
HMDB0000645_ms_ms_1658 | Thermo Q Exactive HF | Quattro_QQQ | - | - | - | negative | MS2 |
HMDB0000645_ms_ms_1659 | Thermo Q Exactive HF | Quattro_QQQ | - | - | - | negative | MS2 |
BAF_UVA_POS001380 | Thermo Q Exactive HF | - | - | - | - | - | - |
BAF_UVA_POS001381 | Thermo Q Exactive HF | - | - | - | - | - | - |