MoNA MS database records for Hesperetin
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
BML00282 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M+H]+ | positive | MS2 |
BML00291 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M+H]+ | positive | MS2 |
BML00300 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M+H]+ | positive | MS2 |
BML00307 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
BML00311 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
BML00315 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M-H]- | negative | MS2 |
BML81380 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML81381 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML81382 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
BML81383 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
VF-NPL-QTOF007969 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007970 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF007971 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
MetaboBASE0470 | impact HD | LC-ESI-TOF | ESI | 10 | - | negative | - |
MetaboBASE0471 | impact HD | LC-ESI-TOF | ESI | 20 | [M-H]- | negative | MS2 |
MetaboBASE0472 | impact HD | LC-ESI-TOF | ESI | 40 | [M-H]- | negative | MS2 |
MetaboBASE0473 | impact HD | LC-ESI-TOF | ESI | - | - | negative | - |
MetaboBASE0474 | impact HD | LC-ESI-TOF | ESI | 10 | [M-H]- | negative | MS2 |
MetaboBASE0475 | impact HD | LC-ESI-TOF | ESI | 30 | [M-H]- | negative | MS2 |
PR309314 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M-H]- | negative | MS2 |
PR309441 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M-H]- | negative | MS2 |
PR311002 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M+H]+ | positive | MS2 |
FiehnLib000476 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000477 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000478 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0030746_c_ms_100559 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0030746_c_ms_100560 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
HMDB0030746_c_ms_100561 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
FIO00130 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
FIO00131 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
FIO00132 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
FIO00133 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
FIO00134 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 50 eV | [M+H]+ | positive | MS2 |
FIO00135 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
FIO00136 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
FIO00137 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
FIO00138 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
FIO00139 | maXis (Bruker Daltonics) | LC-ESI-QTOF | ESI | 50 eV | [M-H]- | negative | MS2 |
CCMSLIB00000845947 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000077230 | qTof | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000078875 | qTof | - | - | - | [M+H]+ | positive | MS2 |
PT207800 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
VF-NPL-LTQ003647 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ003648 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ003649 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ003650 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ007087 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ007088 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-LTQ007089 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ007090 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-QEHF013201 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013202 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013203 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013204 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013205 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013206 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013819 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013820 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013821 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013822 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013823 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013824 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
PS078001 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS078002 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS078003 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS078004 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS078005 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PS078007 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS078008 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PS078009 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M-H]- | negative | MS2 |
PR100772 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
RIKENPlaSMA002864 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002870 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002876 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002882 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002888 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002894 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002900 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002906 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002912 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002918 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002924 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002930 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA006554 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006560 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006566 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006572 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006578 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006584 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006590 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006595 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006600 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006606 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006611 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA006616 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
Bruker_HCD_library001940 | Waters Xevo G2 Q-Tof | - | - | - | [M+H]+ | positive | MS2 |
EAD000511 | Waters Xevo G2 Q-Tof | - | - | - | [M+H]+ | - | - |