MoNA MS database records for Histamine
| Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
|---|---|---|---|---|---|---|---|
| BML81400 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
| BML81401 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
| BML81402 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
| MoNA010708 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | Positive | MS2 |
| MoNA010709 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | Positive | MS2 |
| MoNA010710 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | Positive | MS2 |
| MoNA032172 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA032173 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA032176 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA036100 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA036101 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA036102 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA001986 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
| MoNA001987 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
| MoNA001989 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
| KO003128 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
| KO003129 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
| KO003130 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
| KO003131 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
| KO003132 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
| AU530907 | Bruker maXis Impact | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
| CCMSLIB00005463936 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
| KZ000214 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| OUF00266 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| PR010122 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| CCMSLIB00000578003 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
| CCMSLIB00000578248 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
| CCMSLIB00005720444 | qTof | - | - | - | [M+H]+ | positive | MS2 |
| PT101260 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
| FiehnHILIC000413 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| FiehnHILIC001245 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
| MoNA037194 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| MoNA038578 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| EMBL-MCF_spec123342 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
| EMBL-MCF_spec123437 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
| EMBL-MCF_spec52323 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
| MoNA024068 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
| PS012601 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
| PS012602 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
| PS012603 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
| PR100071 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
| MoNA016721 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
| BAF_UVA_POS001576 | XEVO-G2S | - | - | - | - | - | - |
| BAF_UVA_POS001577 | XEVO-G2S | - | - | - | - | - | - |
| BAF_UVA_POS001578 | XEVO-G2S | - | - | - | - | - | - |
| HMDB0000870_c_ms_1293 | XEVO-G2S | GC-MS | - | - | - | - | - |
| HMDB0000870_c_ms_1582 | XEVO-G2S | GC-MS | - | - | - | - | - |
| HMDB0000870_ei_ms_425 | XEVO-G2S | - | - | - | - | - | - |
| HMDB0000870_ms_ms_1223 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000870_ms_ms_1224 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000870_ms_ms_1225 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
| HMDB0060263_c_ms_1293 | XEVO-G2S | GC-MS | - | - | - | - | - |
| HMDB0060263_c_ms_1582 | XEVO-G2S | GC-MS | - | - | - | - | - |
| HMDB0060263_ei_ms_425 | XEVO-G2S | - | - | - | - | - | - |
| HMDB0060263_ms_ms_1223 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
| HMDB0060263_ms_ms_1224 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
| HMDB0060263_ms_ms_1225 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
| MoNA041268 | XEVO-G2S | - | Electrospray Ionization (ESI) | - | M+H | positive | MS2 |