MoNA MS database records for L-Cystine
| Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
|---|---|---|---|---|---|---|---|
| CCMSLIB00005464452 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
| EMBL-MCF_spec18002 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
| EMBL-MCF_spec209344 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
| EMBL-MCF_spec209349 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
| FiehnHILIC001135 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
| MoNA018187 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
| MoNA018188 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
| MoNA018189 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M-H]- | negative | MS2 |
| MoNA018190 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M-H]- | negative | MS2 |
| MoNA024293 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
| PM001005 | API 2000 | QqQ | ESI | -12 | [M-H]- | negative | MS2 |
| PS027007 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
| VF-NPL-LTQ007403 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
| VF-NPL-QEHF025391 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
| CCMSLIB00005464472 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
| CCMSLIB00005464473 | Orbitrap | - | - | - | [M-2H2O+H]+ | positive | MS2 |
| CCMSLIB00005720335 | qTof | - | - | - | [M+H]+ | positive | MS2 |
| CE000596 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 25.0eV | [M+H]+ | positive | MS2 |
| CE000597 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 5.0eV | [M+H]+ | positive | MS2 |
| CE000598 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35.0eV | [M+H]+ | positive | MS2 |
| CE000599 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 20.0eV | [M+H]+ | positive | MS2 |
| CE000600 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 30.0eV | [M+H]+ | positive | MS2 |
| CE000601 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 45.0eV | [M+H]+ | positive | MS2 |
| CE000602 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 40.0eV | [M+H]+ | positive | MS2 |
| FiehnHILIC000291 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| FiehnLib000129 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
| FiehnLib000438 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
| HMDB0000192_ms_ms_307 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000192_ms_ms_308 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
| HMDB0000192_ms_ms_309 | Leco Pegasus IV | Quattro_QQQ | - | - | - | positive | - |
| KZ000223 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| MoNA002215 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
| MoNA016736 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
| MoNA019027 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
| MoNA019028 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
| MoNA019029 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
| MoNA019030 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
| MoNA019031 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
| MoNA019032 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
| MoNA019033 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
| MoNA019034 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
| MoNA019035 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
| MoNA019036 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
| MoNA019037 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
| MoNA019038 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
| MoNA019772 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
| MoNA019774 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
| MoNA019775 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
| MoNA019776 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M+H]+ | positive | MS2 |
| MoNA024272 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
| MoNA032420 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
| MoNA032425 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
| MoNA032426 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
| MoNA037295 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
| PB000448 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
| PM000966 | API 2000 | QqQ | ESI | 40 | [M+H]+ | positive | MS2 |
| PR010057 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
| PS027001 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
| PS027002 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
| PS027003 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
| RP014401 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
| RP014402 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
| RP014403 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
| VF-NPL-QEHF025388 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
| VF-NPL-QEHF025394 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
| VF-NPL-QEHF025395 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
| VF-NPL-QEHF025396 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
| VF-NPL-QEHF025398 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
| VF-NPL-QEHF025401 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+NH4]+ | positive | MS2 |
| HMDB0000192_c_ms_1955 | Thermo Q Exactive HF | GC-MS | - | - | - | - | - |
| HMDB0000192_ei_ms_1720 | Thermo Q Exactive HF | - | - | - | - | - | - |