MoNA MS database records for L-Lysine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA011147 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
MoNA011148 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
MoNA011149 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
MoNA011150 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
MoNA019021 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA019022 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA019023 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA019024 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA019025 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA019026 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA019753 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
MoNA019754 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
MoNA019755 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M+H]+ | positive | MS2 |
MoNA019756 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
OUF01014 | Agilent 7000B QqQMS, Agilent; ... | GC-EI-QQ | - | - | - | positive | MS1 |
MoNA031980 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA031982 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA031986 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA032713 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032714 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032715 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA033734 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA033736 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA033738 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA035932 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA035933 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA035934 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA001800 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA002276 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
MoNA002277 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
PM000932 | API 2000 | QqQ | ESI | 22 | [M+H]+ | positive | MS2 |
KO001265 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO001266 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO001267 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
KO001268 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO001269 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
KO003282 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO003283 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO003284 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO003285 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO003286 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
PB000429 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
PB000430 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
PR030012 | CE-system connected to 6210 Ti... | CE-ESI-TOF | ESI | - | [M+H]+ | positive | MS1 |
GLS00119 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | - | positive | MS1 |
GLS00120 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | - | positive | MS1 |
FiehnLib001087 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
ML004701 | LTQ Orbitrap Velos Thermo Scie... | LC-ESI-ITFT | ESI | 50 % (nominal) | [M+H]+ | positive | MS2 |
KNA00069 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00070 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
KNA00071 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
KNA00072 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
KNA00256 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00258 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
RP001101 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP001102 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP001103 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
RP001112 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
CCMSLIB00005463974 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005463999 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005464014 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464026 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
KZ000234 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
OUF00315 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR010062 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00000479712 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000577908 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000577950 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000578141 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720352 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720392 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720642 | qTof | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720682 | qTof | - | - | - | [M-H]- | negative | MS2 |
PT102810 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT107190 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT207190 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
FiehnHILIC002071 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC002808 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FiehnHILIC000500 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001306 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA037051 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037117 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037821 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038480 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038519 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
EMBL-MCF_spec103640 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec110458 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec28590 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec28611 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec356279 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec387792 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec387804 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
MoNA024223 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA024227 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
PS028101 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS028102 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS028103 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS028104 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS028106 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M+H]+ | positive | MS2 |
PS071901 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS071902 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS071903 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS071904 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS071905 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PR100167 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100322 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100756 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
MoNA016942 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
MoNA016948 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+Na]+ | positive | - |
HMDB0000182_c_ms_1365 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0000182_c_ms_1547 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0000182_c_ms_1644 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0000182_ms_ms_289 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000182_ms_ms_290 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000182_ms_ms_291 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0003405_c_ms_1365 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0003405_c_ms_1547 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0003405_c_ms_1644 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0003405_ms_ms_289 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0003405_ms_ms_290 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0003405_ms_ms_291 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
MoNA002385 | XEVO-G2S | - | - | - | - | positive | MS1 |
MoNA002472 | XEVO-G2S | - | - | - | - | positive | MS1 |
MoNA002563 | XEVO-G2S | - | - | - | - | positive | MS1 |
MoNA003323 | XEVO-G2S | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 10(NCE) | [M+H]+ | positive | MS2 |
MoNA003324 | XEVO-G2S | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 30(NCE) | [M+H]+ | positive | MS2 |
MoNA003325 | XEVO-G2S | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 40(NCE) | [M+H]+ | positive | MS2 |
MoNA003326 | XEVO-G2S | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 50(NCE) | [M+H]+ | positive | MS2 |
MoNA003327 | XEVO-G2S | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 70(NCE) | [M+H]+ | positive | MS2 |
MoNA003328 | XEVO-G2S | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 90(NCE) | [M+H]+ | positive | MS2 |