MoNA MS database records for Lipoamide

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
MoNA023887Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M-H]-negativeMS2
MoNA023868Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M+H]+positiveMS2
PS021501TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS062701TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS021502TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PS062702TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
MoNA034421Agilent qTOF 6545LC-ESI-QTOF-10 eV[M-H]-negativeMS2
MoNA034422Agilent qTOF 6545LC-ESI-QTOF-20 eV[M-H]-negativeMS2
MoNA034420Agilent qTOF 6545LC-ESI-QTOF-40 eV[M-H]-negativeMS2
MoNA032385Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA036283Agilent qTOF 6545LC-ESI-QTOF-10 eV[M+H]+positiveMS2
MoNA032389Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA036281Agilent qTOF 6545LC-ESI-QTOF-20 eV[M+H]+positiveMS2
MoNA032391Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
MoNA036282Agilent qTOF 6545LC-ESI-QTOF-40 eV[M+H]+positiveMS2
KO003312API3000, Applied BiosystemsLC-ESI-QQ-10 V[M+H]+positiveMS2
KO003313API3000, Applied BiosystemsLC-ESI-QQ-20 V[M+H]+positiveMS2
KO003314API3000, Applied BiosystemsLC-ESI-QQ-30 V[M+H]+positiveMS2
KO003315API3000, Applied BiosystemsLC-ESI-QQ-40 V[M+H]+positiveMS2
KO003316API3000, Applied BiosystemsLC-ESI-QQ-50 V[M+H]+positiveMS2
KO009031LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.55[M+H]+positiveMS2
KO009032LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-0.55/0.55[M+H]+positiveMS3
KO009033LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT-1.20/0.40[M+H]+positiveMS3
FiehnLib000801Leco Pegasus IVGC-EI-TOF---positiveMS1
FiehnLib000802Leco Pegasus IVGC-EI-TOF---positiveMS1
CCMSLIB00005464349Orbitrap---[M+Na]+positiveMS2
CCMSLIB00000578066Q-Exactive Plus---[M+H]+positiveMS2
CCMSLIB00005720523qTof---[M+H]+positiveMS2
FiehnHILIC002057SCIEX TripleTOF 6600LC-ESI-QTOF-35 eV[M+H]+positiveMS2
MoNA038007Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
FiehnHILIC000485Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA037277Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA038646Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M+H]+positiveMS2
MoNA016893XEVO-G2SLC-ESI-QTOF-6V (MS1); Ramp 15V-30V (MSE)[M+Na]+positive-
HMDB0000962_ms_ms_1366XEVO-G2SQuattro_QQQ---positive-
HMDB0000962_ms_ms_1367XEVO-G2SQuattro_QQQ---positive-
HMDB0000962_ms_ms_1368XEVO-G2SQuattro_QQQ---positive-
BAF_UVA_POS001049XEVO-G2S------
BAF_UVA_POS001050XEVO-G2S------
BAF_UVA_POS001051XEVO-G2S------
BAF_UVA_POS001052XEVO-G2S------
BAF_UVA_POS001273XEVO-G2S------
HMDB0000962_c_ms_1777XEVO-G2SGC-MS-----
HMDB0000962_c_ms_1855XEVO-G2SGC-MS-----