Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
PM000412API 3000QqQESI-30[M-H]-negativeMS2
PN000059micrOTOF-QESI-TOFESI25 eV[M-H]-negativeMS2
PN000060micrOTOF-QESI-TOFESI15 eV[M+H]+positiveMS2
PT204260Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M-H]-negativeMS2
PT104260Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M+H]+positiveMS2
PS042607TQD, WatersFlow-injection QqQ/MSESI10[M-H]-negativeMS2
PS042608TQD, WatersFlow-injection QqQ/MSESI20[M-H]-negativeMS2
PS042609TQD, WatersFlow-injection QqQ/MSESI30[M-H]-negativeMS2
PS042610TQD, WatersFlow-injection QqQ/MSESI40[M-H]-negativeMS2
PS042611TQD, WatersFlow-injection QqQ/MSESI50[M-H]-negativeMS2
PS042612TQD, WatersFlow-injection QqQ/MSESI60[M-H]-negativeMS2
PS042601TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS042602TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PS042603TQD, WatersFlow-injection QqQ/MSESI30[M+H]+positiveMS2
PS042604TQD, WatersFlow-injection QqQ/MSESI40[M+H]+positiveMS2
PS042605TQD, WatersFlow-injection QqQ/MSESI50[M+H]+positiveMS2
PS042606TQD, WatersFlow-injection QqQ/MSESI60[M+H]+positiveMS2
PR040138UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI30 V[2M-H]-negativeMS2
PR040136UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[2M-H]-negativeMS2
PR040137UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI30 V[M-H]-negativeMS2
PR040135UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR100669UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR040141UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[2M+H]+positiveMS2
PR020062UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI5.0 V[M+H]+positiveMS1
PR040139UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI30 V[M+H]+positiveMS2
PR040140UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
PR100247UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
CB000316ABSciex API3200 LC/MS systemLC-ESI-QQQ--[M+H]+positiveMS1
BML00142Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF-20 ev[M-H]-negativeMS2
TY000146LCMS-IT-TOFLC-ESI-ITTOF--[M+H]+positiveMS2
TY000145LCMS-IT-TOFLC-ESI-ITTOF---positiveMS1
RIKENPlaSMA005563Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA005569Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA005588Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA005594Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA005612Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA005617Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA005576Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M-H]-negativeMS2
RIKENPlaSMA005600Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M-H]-negativeMS2
RIKENPlaSMA005624Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M-H]-negativeMS2
RIKENPlaSMA005582Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M-H]-negativeMS2
RIKENPlaSMA005606Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M-H]-negativeMS2
RIKENPlaSMA005631Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M-H]-negativeMS2
RIKENPlaSMA002004Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002010Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002028Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002034Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002051Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002057Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002016Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA002040Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA002063Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA002022Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
RIKENPlaSMA002046Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
RIKENPlaSMA002069Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2