MoNA MS database records for Naringenin-7-O-glucoside

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
MetaboBASE0367impact HDLC-ESI-TOFESI20[M-H]-negativeMS2
MetaboBASE0370impact HDLC-ESI-TOFESI40[M-H]-negativeMS2
MetaboBASE0369impact HDLC-ESI-TOFESI10-negative-
MetaboBASE0368impact HDLC-ESI-TOFESI--negative-
PR309316LC, Waters Acquity UPLC System...LC-ESI-QTOFESI6V[M-H]-negativeMS2
PR311003LC, Waters Acquity UPLC System...LC-ESI-QTOFESI6V[M+H]+positiveMS2
PT204280Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M-H]-negativeMS2
PT104280Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M+H]+positiveMS2
PS042807TQD, WatersFlow-injection QqQ/MSESI10[M-H]-negativeMS2
PS042808TQD, WatersFlow-injection QqQ/MSESI20[M-H]-negativeMS2
PS042809TQD, WatersFlow-injection QqQ/MSESI30[M-H]-negativeMS2
PS042810TQD, WatersFlow-injection QqQ/MSESI40[M-H]-negativeMS2
PS042811TQD, WatersFlow-injection QqQ/MSESI50[M-H]-negativeMS2
PS042801TQD, WatersFlow-injection QqQ/MSESI10[M+H]+positiveMS2
PS042802TQD, WatersFlow-injection QqQ/MSESI20[M+H]+positiveMS2
PS042803TQD, WatersFlow-injection QqQ/MSESI30[M+H]+positiveMS2
PS042804TQD, WatersFlow-injection QqQ/MSESI40[M+H]+positiveMS2
PS042805TQD, WatersFlow-injection QqQ/MSESI50[M+H]+positiveMS2
PS042806TQD, WatersFlow-injection QqQ/MSESI60[M+H]+positiveMS2
PR040151UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI30 V[M-H]-negativeMS2
PR040149UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR100671UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR040152UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI30 V[M-H-C6H10O5]-negativeMS2
PR040150UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H-C6H10O5]-negativeMS2
PR020069UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI5.0 V[M+H]+positiveMS1
PR040155UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI30 V[M+H]+positiveMS2
PR040153UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
PR100249UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H]+positiveMS2
PR040156UPLC Q-Tof Premier, WatersLC-ESI-QTOFESI30 V[M+H-C6H10O5]+positiveMS2
PR040154UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M+H-C6H10O5]+positiveMS2
VF-NPL-QTOF004555Agilent 6530 Q-TOFLC-ESI-QTOF-10 V[M-H]-negativeMS2
VF-NPL-QTOF009066Agilent 6530 Q-TOFLC-ESI-QTOF-10 V[M-H]-negativeMS2
VF-NPL-QTOF004556Agilent 6530 Q-TOFLC-ESI-QTOF-20 V[M-H]-negativeMS2
VF-NPL-QTOF009067Agilent 6530 Q-TOFLC-ESI-QTOF-20 V[M-H]-negativeMS2
VF-NPL-QTOF004557Agilent 6530 Q-TOFLC-ESI-QTOF-40 V[M-H]-negativeMS2
VF-NPL-QTOF009068Agilent 6530 Q-TOFLC-ESI-QTOF-40 V[M-H]-negativeMS2
VF-NPL-QTOF004552Agilent 6530 Q-TOFLC-ESI-QTOF-10 V[M+H]+positiveMS2
VF-NPL-QTOF009069Agilent 6530 Q-TOFLC-ESI-QTOF-10 V[M+H]+positiveMS2
VF-NPL-QTOF004553Agilent 6530 Q-TOFLC-ESI-QTOF-20 V[M+H]+positiveMS2
VF-NPL-QTOF009070Agilent 6530 Q-TOFLC-ESI-QTOF-20 V[M+H]+positiveMS2
VF-NPL-QTOF004554Agilent 6530 Q-TOFLC-ESI-QTOF-40 V[M+H]+positiveMS2
VF-NPL-QTOF009071Agilent 6530 Q-TOFLC-ESI-QTOF-40 V[M+H]+positiveMS2
VF-NPL-QTOF004558Agilent 6530 Q-TOFLC-ESI-QTOF-10 V[M+Na]+positiveMS2
VF-NPL-QTOF009072Agilent 6530 Q-TOFLC-ESI-QTOF-10 V[M+Na]+positiveMS2
VF-NPL-QTOF004559Agilent 6530 Q-TOFLC-ESI-QTOF-20 V[M+Na]+positiveMS2
VF-NPL-QTOF009073Agilent 6530 Q-TOFLC-ESI-QTOF-20 V[M+Na]+positiveMS2
FiehnLib000870Leco Pegasus IVGC-EI-TOF---positiveMS1
FiehnLib000871Leco Pegasus IVGC-EI-TOF---positiveMS1
VF-NPL-LTQ000024Thermo Finnigan LTQLinear Ion Trap-35M-HnegativeMS2-MS4 Composite
VF-NPL-LTQ000021Thermo Finnigan LTQLinear Ion Trap-35M-HpositiveMS2
VF-NPL-LTQ000022Thermo Finnigan LTQLinear Ion Trap-35M-HpositiveMS2-MS5 Composite
VF-NPL-QEHF000067Thermo Q Exactive HFESI-QFT-25HCD[M-H]-negativeMS2
VF-NPL-QEHF000068Thermo Q Exactive HFESI-QFT-35HCD[M-H]-negativeMS2
VF-NPL-QEHF000069Thermo Q Exactive HFESI-QFT-45HCD[M-H]-negativeMS2
VF-NPL-QEHF000070Thermo Q Exactive HFESI-QFT-25HCD[M+H]+positiveMS2
VF-NPL-QEHF000071Thermo Q Exactive HFESI-QFT-35HCD[M+H]+positiveMS2
VF-NPL-QEHF000072Thermo Q Exactive HFESI-QFT-45HCD[M+H]+positiveMS2
RIKENPlaSMA006364Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA006370Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA006388Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA006393Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA006410Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA006415Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M-H]-negativeMS2
RIKENPlaSMA006376Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M-H]-negativeMS2
RIKENPlaSMA006398Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M-H]-negativeMS2
RIKENPlaSMA006421Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M-H]-negativeMS2
RIKENPlaSMA006382Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M-H]-negativeMS2
RIKENPlaSMA006404Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M-H]-negativeMS2
RIKENPlaSMA006427Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M-H]-negativeMS2
RIKENPlaSMA002695Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002700Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002715Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002720Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002735Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002740Waters Xevo G2 Q-TofLC-ESI-QTOF-10 eV[M+H]+positiveMS2
RIKENPlaSMA002705Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA002725Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA002745Waters Xevo G2 Q-TofLC-ESI-QTOF-30 eV[M+H]+positiveMS2
RIKENPlaSMA002710Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
RIKENPlaSMA002730Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
RIKENPlaSMA002750Waters Xevo G2 Q-TofLC-ESI-QTOF-50 eV[M+H]+positiveMS2
  logo