MoNA MS database records for Naringin
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA003263 | Q Exactive Orbitrap Thermo Sci... | LC-ESI-QFT | Electrospray Ionization (ESI) | Stepped (NCE 20-30-40%) | [M-H]- | negative | MS2 |
PM000416 | API 3000 | QqQ | ESI | -35 | [M-H]- | negative | MS2 |
PB000783 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
PB000784 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB000785 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB000801 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
PB000802 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 55 eV | [M+H]+ | positive | MS2 |
PB000803 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 25 eV | [M+H-C12H20O9]+ | positive | MS2 |
PB000804 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 40 eV | [M+H-C12H20O9]+ | positive | MS2 |
MetaboBASE0384 | impact HD | LC-ESI-TOF | ESI | 10 | [M-H]- | negative | MS2 |
MetaboBASE0385 | impact HD | LC-ESI-TOF | ESI | 20 | [M-H]- | negative | MS2 |
MetaboBASE0386 | impact HD | LC-ESI-TOF | ESI | 30 | [M-H]- | negative | MS2 |
MetaboBASE0383 | impact HD | LC-ESI-TOF | ESI | 40 | [M-H]- | negative | MS2 |
MetaboBASE0387 | impact HD | LC-ESI-TOF | ESI | 50 | [M-H]- | negative | MS2 |
MetaboBASE0382 | impact HD | LC-ESI-TOF | ESI | 10 | - | negative | - |
PR310487 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | ESI | 6V | [M+H]+ | positive | MS2 |
CE000186 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
CE000187 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 45eV | [M+H]+ | positive | MS2 |
CE000188 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 55eV | [M+H]+ | positive | MS2 |
CE000189 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 70eV | [M+H]+ | positive | MS2 |
CE000190 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | - | - | positive | MS1 |
PB005722 | micrOTOF-Q | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
PB005723 | micrOTOF-Q | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB005724 | micrOTOF-Q | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
PB005725 | micrOTOF-Q | LC-ESI-QTOF | ESI | 25 eV | [M+H]+ | positive | MS2 |
PB005726 | micrOTOF-Q | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
BML01161 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
BML01170 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
BML01179 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M-H]- | negative | MS2 |
BML81786 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML81788 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
BML81785 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
VF-NPL-QTOF009074 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF009075 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF009076 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF004563 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009080 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF004564 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009081 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF004565 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009082 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF000833 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF000834 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF000835 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF004566 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009083 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004567 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009084 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004568 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009085 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF000836 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF000837 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF000838 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004560 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF009077 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF004561 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF009078 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF004562 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF009079 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
FiehnLib000866 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0002927_c_ms_99786 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | - |
FiehnHILIC002874 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FiehnHILIC002171 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
TY000029 | Shimadzu LC20A-IT-TOFMS | LC-ESI-ITTOF | - | - | [M-H]- | negative | MS1 |
VF-NPL-LTQ003659 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ007047 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ003660 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ006004 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ007048 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ006001 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ006002 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-QEHF013225 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013729 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013226 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013730 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013227 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013731 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
FiehnHILIC001390 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
VF-NPL-QEHF013228 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013732 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013229 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013733 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013230 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013734 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
FiehnHILIC000602 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013234 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF013235 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF013236 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF013231 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF013735 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF013232 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF013736 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF013233 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF013737 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
RIKENPlaSMA007589 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007605 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007622 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007630 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007617 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA007634 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA003709 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003712 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003720 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003723 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003732 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003735 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003715 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003726 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003738 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003729 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA003741 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
HMDB0002927_ms_ms_285587 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0002927_ms_ms_285588 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0002927_ms_ms_285589 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0002927_ms_ms_285590 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0002927_ms_ms_285591 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0002927_ms_ms_285592 | Waters Xevo G2 Q-Tof | ESI-TOF | - | - | - | negative | - |
HMDB0002927_ms_ms_2169 | Waters Xevo G2 Q-Tof | Quattro_QQQ | - | - | - | positive | - |