MoNA MS database records for Norepinephrine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
CCMSLIB00005464136 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005464210 | Orbitrap | - | - | - | [M-H2O+H]+ | positive | MS2 |
CCMSLIB00005464211 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005720660 | qTof | - | - | - | [M-H]- | negative | MS2 |
FiehnHILIC001402 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnLib000656 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
HMDB0000216_c_ms_1837 | Leco Pegasus IV | GC-MS | - | - | - | - | - |
HMDB0000216_ms_ms_355 | Leco Pegasus IV | Quattro_QQQ | - | - | - | N/A | - |
HMDB0000216_ms_ms_356 | Leco Pegasus IV | Quattro_QQQ | - | - | - | N/A | - |
HMDB0000216_ms_ms_357 | Leco Pegasus IV | Quattro_QQQ | - | - | - | N/A | - |
JP001410 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
KO003612 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO003613 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO003614 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO003615 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO003616 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
MoNA001700 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA001702 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA001703 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
MoNA011223 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
MoNA011224 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
MoNA011225 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
MoNA019386 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA019387 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA019388 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA019929 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
MoNA019930 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
MoNA019931 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M+H]+ | positive | MS2 |
MoNA019932 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
MoNA032624 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032625 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032628 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA037380 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
PM002305 | API 3000 | QqQ | ESI | 10->40V | [M+H]+ | positive | MS2 |
PS001401 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS001402 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS001406 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M+H]+ | positive | MS2 |