MoNA MS database records for Pyridoxine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PT203320 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT103320 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
MoNA024296 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA024278 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
PS033207 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS033201 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS033202 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS033203 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PR100602 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR100196 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004745 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009441 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF004746 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009442 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF004747 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009443 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF004748 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009444 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004749 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009445 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF004750 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009446 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
MoNA011305 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
MoNA011306 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
MoNA011307 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
MoNA011308 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
MoNA034735 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034732 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034733 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA032606 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032604 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032607 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA002291 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA002293 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA002296 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 40 | [M+H]+ | positive | MS2 |
KO001636 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO001637 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO001638 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
KO001639 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO001640 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
KO003753 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO003754 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO003755 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO003756 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO003757 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
JP006258 | HITACHI M-80 | EI-B | - | - | [M]+* | positive | MS1 |
FiehnLib000316 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00005464122 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005464265 | Orbitrap | - | - | - | [M-2H2O+H]+ | positive | MS2 |
CCMSLIB00000479732 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464262 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005464263 | Orbitrap | - | - | - | [M-H2O+H]+ | positive | MS2 |
CCMSLIB00005464264 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
KZ000070 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
OUF00436 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR010229 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00000578147 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000577914 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720647 | qTof | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720357 | qTof | - | - | - | [M+H]+ | positive | MS2 |
FiehnHILIC002284 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
VF-NPL-LTQ007756 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ007754 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-QEHF028159 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF028160 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF028161 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
FiehnHILIC001474 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
MoNA038122 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
VF-NPL-QEHF028156 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF028157 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF028158 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
FiehnHILIC000720 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037369 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
VF-NPL-QEHF028165 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF028166 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF028167 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF028162 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF028163 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF028164 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF028168 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF028169 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF028170 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+NH4]+ | positive | MS2 |
EMBL-MCF_spec27827 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec102796 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
MoNA016785 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
HMDB0000239_ms_ms_403 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000239_ms_ms_404 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
HMDB0000239_ms_ms_405 | XEVO-G2S | Quattro_QQQ | - | - | - | positive | - |
BAF_UVA_POS000162 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000163 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000164 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000165 | XEVO-G2S | - | - | - | - | - | - |
BAF_UVA_POS000868 | XEVO-G2S | - | - | - | - | - | - |
HMDB0000239_c_ms_1609 | XEVO-G2S | GC-MS | - | - | - | - | - |
HMDB0000239_ei_ms_1069 | XEVO-G2S | - | - | - | - | - | - |