Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
PM000410 | API 3000 | QqQ | ESI | -30 | [M-H]- | negative | MS2 |
MetaboBASE0308 | impact HD | LC-ESI-TOF | ESI | 20 | [M-H]- | negative | MS2 |
MetaboBASE0309 | impact HD | LC-ESI-TOF | ESI | 40 | [M-H]- | negative | MS2 |
MetaboBASE0310 | impact HD | LC-ESI-TOF | ESI | 50 | [M-H]- | negative | MS2 |
MetaboBASE0305 | impact HD | LC-ESI-TOF | ESI | 60 | [M-H]- | negative | MS2 |
MetaboBASE0306 | impact HD | LC-ESI-TOF | ESI | 70 | [M-H]- | negative | MS2 |
MetaboBASE0307 | impact HD | LC-ESI-TOF | ESI | 10 | - | negative | - |
FIO00913 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 10 eV | [M-H]- | negative | MS2 |
FIO00914 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 20 eV | [M-H]- | negative | MS2 |
FIO00915 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 30 eV | [M-H]- | negative | MS2 |
FIO00916 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 40 eV | [M-H]- | negative | MS2 |
FIO00917 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 50 eV | [M-H]- | negative | MS2 |
FIO00909 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
FIO00910 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
FIO00911 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
FIO00912 | maXis, Bruker Daltonics | LC-ESI-QTOF | ESI | 40 eV | [M+H]+ | positive | MS2 |
PN000127 | micrOTOF-Q | ESI-TOF | ESI | 25 eV | [M-H]- | negative | MS2 |
PN000128 | micrOTOF-Q | ESI-TOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PT208740 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
PT108740 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PS087407 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PS087408 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M-H]- | negative | MS2 |
PS087409 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M-H]- | negative | MS2 |
PS087410 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M-H]- | negative | MS2 |
PS087411 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M-H]- | negative | MS2 |
PS087412 | TQD, Waters | Flow-injection QqQ/MS | ESI | 60 | [M-H]- | negative | MS2 |
PS087401 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS087402 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS087403 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS087405 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
PR100820 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PR020029 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | 5.0 V | [M+H]+ | positive | MS1 |
PR100370 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
CCMSLIB00000081773 | qTof | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000081772 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000578415 | qTof | - | - | - | [M+H]+ | positive | MS2 |
FiehnHILIC003052 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
FiehnHILIC002417 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnHILIC001577 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC000856 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
RIKENPlaSMA006228 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M-H]- | negative | MS2 |
RIKENPlaSMA002551 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002557 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002575 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002581 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002599 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002605 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002563 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002587 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002611 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 30 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002569 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002593 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |
RIKENPlaSMA002617 | Waters Xevo G2 Q-Tof | LC-ESI-QTOF | - | 50 eV | [M+H]+ | positive | MS2 |