MoNA MS database records for Xanthine

Massbank ID Instrument Inst. type MS type Collision energy Ion type Ion mode MS level
FiehnLib001042Leco Pegasus IVGC-EI-TOF---positiveMS1
MoNA041154Leco Pegasus IV-Electron Impact (EI)--positiveMS1
OUF00489Pegasus III TOF-MS system, Lec...GC-EI-TOF---positiveMS1
CCMSLIB00000479754Q-Exactive Plus---[M-H]-negativeMS2
CCMSLIB00000578121Q-Exactive Plus---[M-H]-negativeMS2
CCMSLIB00005464049Orbitrap---[M-H]-negativeMS2
CCMSLIB00005464098Orbitrap---[M+H]+positiveMS2
EMBL-MCF_spec17909Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M-H]-negativeMS2
EMBL-MCF_spec17922Thermo Q-Exactive PlusLC-ESI-QFT-35.0 eV[M-H]-negativeMS2
MoNA002211Agilent QTOF 6550LC-ESI-QTOF-20[M+H]+positiveMS2
MoNA002212Agilent QTOF 6550LC-ESI-QTOF-10[M+H]+positiveMS2
MoNA002213Agilent QTOF 6550LC-ESI-QTOF-40[M+H]+positiveMS2
MoNA010244Agilent 6550 iFunnelLC-ESI-QTOF--[M+H]+PositiveMS2
MoNA010245Agilent 6550 iFunnelLC-ESI-QTOF-10[M+H]+PositiveMS2
MoNA010246Agilent 6550 iFunnelLC-ESI-QTOF-30[M+H]+PositiveMS2
MoNA010247Agilent 6550 iFunnelLC-ESI-QTOF--[M+H]+PositiveMS2
MoNA010248Agilent 6550 iFunnelLC-ESI-QTOF-10[M+H]+PositiveMS2
MoNA010249Agilent 6550 iFunnelLC-ESI-QTOF-30[M+H]+PositiveMS2
MoNA017681Agilent 6550 iFunnelLC-ESI-QTOFESI10[M-H]-negativeMS2
MoNA017682Agilent 6550 iFunnelLC-ESI-QTOFESI20[M-H]-negativeMS2
MoNA017683Agilent 6550 iFunnelLC-ESI-QTOFESI30[M-H]-negativeMS2
MoNA017684Agilent 6550 iFunnelLC-ESI-QTOFESI40[M-H]-negativeMS2
MoNA024324Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M-H]-negativeMS2
MoNA024344Thermo Scientific Orbitrap ID-...LC-ESI-OrbitrapESIHCD (NCE 40%)[M+H]+positiveMS2
MoNA034465Agilent qTOF 6545LC-ESI-QTOF-10 eV[M-H]-negativeMS2
MoNA034466Agilent qTOF 6545LC-ESI-QTOF-20 eV[M-H]-negativeMS2
MoNA034471Agilent qTOF 6545LC-ESI-QTOF-40 eV[M-H]-negativeMS2
MoNA038023Thermo Q Exactive HFLC-ESI-QFT-HCD (NCE 20-30-40%)[M-H]-negativeMS2
MT000100LTQ XL, Thermo FinniganLC-ESI-ITESI40[M+H]+positiveMS2
PR100624UPLC Q-Tof Premier, WatersLC-ESI-QTOFESIRamp 5-60 V[M-H]-negativeMS2
PR310811LC, Waters Acquity UPLC System...LC-ESI-QTOFESI6V[M+H]+positiveMS2
PT203730Q-Tof Premier, WatersLC-Q-TOF/MSESIRamp 5-45 V[M-H]-negativeMS2
RP012501maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI10[M+H]+positiveMS2
RP012502maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI20[M+H]+positiveMS2
RP012503maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOFESI40[M+H]+positiveMS2
BAF_UVA_POS000444maXis plus UHR-ToF-MS, Bruker ...------
BAF_UVA_POS000445maXis plus UHR-ToF-MS, Bruker ...------
BAF_UVA_POS001225maXis plus UHR-ToF-MS, Bruker ...------
HMDB0000292_ei_ms_412maXis plus UHR-ToF-MS, Bruker ...------
HMDB0000292_ms_ms_495maXis plus UHR-ToF-MS, Bruker ...Quattro_QQQ---positive-
HMDB0000292_ms_ms_496maXis plus UHR-ToF-MS, Bruker ...Quattro_QQQ---positive-
HMDB0000292_ms_ms_497maXis plus UHR-ToF-MS, Bruker ...Quattro_QQQ---positive-
MoNA011410Agilent 6550 iFunnelQ-TOF-10[M+H]+positive-
MoNA011411Agilent 6550 iFunnelQ-TOF-20[M+H]+positive-
MoNA011412Agilent 6550 iFunnelQ-TOF-30[M+H]+positive-
MoNA011413Agilent 6550 iFunnelQ-TOF-40[M+H]+positive-
MoNA016816XEVO-G2SLC-ESI-QTOF-6V (MS1); Ramp 15V-30V (MSE)[M+H]+positive-