Massbank MS database records for 5-Hydroxyindoleacetic acid
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-Keio_Univ-KO001066 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001067 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001068 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001069 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001070 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS096807 | TQD, Waters | LC-ESI-QQ | 10 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS096809 | TQD, Waters | LC-ESI-QQ | 30 | - | NEGATIVE | MS2 |
MSBNK-Athens_Univ-AU279501 | Bruker maXis Impact | LC-ESI-QTOF | 10 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Athens_Univ-AU279503 | Bruker maXis Impact | LC-ESI-QTOF | 30 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Athens_Univ-AU279504 | Bruker maXis Impact | LC-ESI-QTOF | 40 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Athens_Univ-AU279505 | Bruker maXis Impact | LC-ESI-QTOF | 50 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Athens_Univ-AU279506 | Bruker maXis Impact | LC-ESI-QTOF | Ramp 17.7-26.6 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-GL_Sciences_Inc-GLS00083 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | POSITIVE | MS |
MSBNK-GL_Sciences_Inc-GLS00084 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | POSITIVE | MS |
MSBNK-IPB_Halle-PB001381 | API QSTAR Pulsar i | LC-ESI-QTOF | 15 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-IPB_Halle-PB001382 | API QSTAR Pulsar i | LC-ESI-QTOF | 25 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-IPB_Halle-PB001383 | API QSTAR Pulsar i | LC-ESI-QTOF | 40 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-IPB_Halle-PB001384 | API QSTAR Pulsar i | LC-ESI-QTOF | 55 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003123 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003124 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003125 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003126 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003127 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Osaka_Univ-OUF00075 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN_ReSpect-PS096801 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS096802 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS096803 | TQD, Waters | LC-ESI-QQ | 30 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS096804 | TQD, Waters | LC-ESI-QQ | 40 | - | POSITIVE | MS2 |