Massbank MS database records for Apigenin

Massbank ID Instrument Inst. type Collision energy Ion type Ion mode MS level
MSBNK-BGC_Munich-RP015101maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF10[M+H]+POSITIVEMS2
MSBNK-BGC_Munich-RP015111maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF10[M-H]-NEGATIVEMS2
MSBNK-RIKEN_ReSpect-PS039301TQD, WatersLC-ESI-QQ10-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS039307TQD, WatersLC-ESI-QQ10-NEGATIVEMS2
MSBNK-Washington_State_Univ-BML00404Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF10 ev[M+H]+POSITIVEMS2
MSBNK-Washington_State_Univ-BML00444Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF10 ev[M-H]-NEGATIVEMS2
MSBNK-Fiocruz-FIO00006maXis (Bruker Daltonics)LC-ESI-QTOF10 eV[M+H]+POSITIVEMS2
MSBNK-Fiocruz-FIO00011maXis (Bruker Daltonics)LC-ESI-QTOF10 eV[M-H]-NEGATIVEMS2
MSBNK-IPB_Halle-PN000010micrOTOF-QESI-TOF15 eV[M+H]+POSITIVEMS2
MSBNK-BGC_Munich-RP015102maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF20[M+H]+POSITIVEMS2
MSBNK-BGC_Munich-RP015112maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF20[M-H]-NEGATIVEMS2
MSBNK-RIKEN_ReSpect-PS039302TQD, WatersLC-ESI-QQ20-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS039308TQD, WatersLC-ESI-QQ20-NEGATIVEMS2
MSBNK-Washington_State_Univ-BML00418Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF20 ev[M+H]+POSITIVEMS2
MSBNK-Washington_State_Univ-BML00454Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF20 ev[M-H]-NEGATIVEMS2
MSBNK-Fiocruz-FIO00007maXis (Bruker Daltonics)LC-ESI-QTOF20 eV[M+H]+POSITIVEMS2
MSBNK-Fiocruz-FIO00012maXis (Bruker Daltonics)LC-ESI-QTOF20 eV[M-H]-NEGATIVEMS2
MSBNK-IPB_Halle-PN000009micrOTOF-QESI-TOF25 eV[M-H]-NEGATIVEMS2
MSBNK-RIKEN_ReSpect-PS039303TQD, WatersLC-ESI-QQ30-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS039309TQD, WatersLC-ESI-QQ30-NEGATIVEMS2
MSBNK-BS-BS003047Bruker impact HDLC-ESI-QTOF30 eV[M-H]-NEGATIVEMS2
MSBNK-Fiocruz-FIO00008maXis (Bruker Daltonics)LC-ESI-QTOF30 eV[M+H]+POSITIVEMS2
MSBNK-Fiocruz-FIO00013maXis (Bruker Daltonics)LC-ESI-QTOF30 eV[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR040002UPLC Q-Tof Premier, WatersLC-ESI-QTOF30 eV-NEGATIVEMS2
MSBNK-RIKEN-PR040003UPLC Q-Tof Premier, WatersLC-ESI-QTOF30 eV-POSITIVEMS2
MSBNK-RIKEN-PR100224UPLC Q-Tof Premier, WatersLC-ESI-QTOF30 V[M+H]+POSITIVEMS2
MSBNK-RIKEN_ReSpect-PT103933Q-Tof Premier, WatersLC-ESI-QTOF30 V-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PM000421Agilent (Waldbronn, Germany) M...LC-ESI-QQ-35-NEGATIVEMS2
MSBNK-BGC_Munich-RP015103maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF40[M+H]+POSITIVEMS2
MSBNK-BGC_Munich-RP015113maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF40[M-H]-NEGATIVEMS2
MSBNK-RIKEN_ReSpect-PS039304TQD, WatersLC-ESI-QQ40-POSITIVEMS2
MSBNK-Washington_State_Univ-BML00464Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF40 ev[M-H]-NEGATIVEMS2
MSBNK-Fiocruz-FIO00009maXis (Bruker Daltonics)LC-ESI-QTOF40 eV[M+H]+POSITIVEMS2
MSBNK-Fiocruz-FIO00014maXis (Bruker Daltonics)LC-ESI-QTOF40 eV[M-H]-NEGATIVEMS2
MSBNK-Fiocruz-FIO00010maXis (Bruker Daltonics)LC-ESI-QTOF50 eV[M+H]+POSITIVEMS2
MSBNK-Fiocruz-FIO00015maXis (Bruker Daltonics)LC-ESI-QTOF50 eV[M-H]-NEGATIVEMS2
MSBNK-MetaboLights-ML002601LTQ Orbitrap Velos Thermo Scie...LC-ESI-ITFT50 % (nominal)[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR020018UPLC Q-Tof Premier, WatersLC-ESI-QTOF5.0 V-POSITIVEMS
MSBNK-RIKEN-PR302935LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302940LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302945LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302950LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302955LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302960LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302965LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302970LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302975LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302980LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302985LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR302990LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR306621LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306625LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306630LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306635LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306640LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306645LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306650LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306655LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306660LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306665LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306670LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR306675LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR309268LC, Waters Acquity UPLC System...LC-ESI-QTOF6V[M-H]-NEGATIVEMS2
MSBNK-RIKEN_ReSpect-PT103930Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-45 V-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PT203930Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-45 V-NEGATIVEMS2
MSBNK-RIKEN-PR040001UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 eV-NEGATIVEMS2
MSBNK-RIKEN-PR040004UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 eV-POSITIVEMS2
MSBNK-RIKEN-PR100223UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR100634UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 V[M-H]-NEGATIVEMS2
MSBNK-BS-BS003048Bruker impact HDLC-ESI-QTOF--NEGATIVEMS
MSBNK-Osaka_Univ-OUF00116Pegasus III TOF-MS system, Lec...GC-EI-TOF--POSITIVEMS
MSBNK-Osaka_Univ-OUF00117Pegasus III TOF-MS system, Lec...GC-EI-TOF--POSITIVEMS
MSBNK-Univ_Toyama-TY000119LCMS-IT-TOFLC-ESI-ITTOF--POSITIVEMS
MSBNK-Washington_State_Univ-BML80760Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF--POSITIVEMS
MSBNK-Washington_State_Univ-BML80761Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF--NEGATIVEMS
MSBNK-Washington_State_Univ-BML80762Agilent 1200 RRLC; Agilent 652...LC-APCI-QTOF--POSITIVEMS
MSBNK-Washington_State_Univ-BML80763Agilent 1200 RRLC; Agilent 652...LC-APCI-QTOF--NEGATIVEMS
  logo