Massbank MS database records for Gentisic acid
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-BS-BS003105 | Bruker impact HD | LC-ESI-QTOF | - | - | NEGATIVE | MS |
MSBNK-BS-BS003106 | Bruker impact HD | LC-ESI-QTOF | 10 eV | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO000574 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO000575 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO000576 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO000577 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO000578 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Osaka_MCHRI-MCH00006 | Voyager DE-PRO, Applied Biosys... | MALDI-TOF | - | - | NEGATIVE | MS |
MSBNK-Osaka_MCHRI-MCH00016 | Voyager DE-PRO, Applied Biosys... | MALDI-TOF | - | - | NEGATIVE | MS |
MSBNK-RIKEN-PR100832 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS095207 | TQD, Waters | LC-ESI-QQ | 10 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS095208 | TQD, Waters | LC-ESI-QQ | 20 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS095209 | TQD, Waters | LC-ESI-QQ | 30 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PT209520 | Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-45 V | - | NEGATIVE | MS2 |
MSBNK-Waters-WA000502 | ZQ, Waters | LC-ESI-Q | - | - | NEGATIVE | MS |
MSBNK-Waters-WA000503 | ZQ, Waters | LC-ESI-Q | - | - | NEGATIVE | MS |
MSBNK-Waters-WA000504 | ZQ, Waters | LC-ESI-Q | - | - | NEGATIVE | MS |
MSBNK-Waters-WA000505 | ZQ, Waters | LC-ESI-Q | - | - | NEGATIVE | MS |
MSBNK-Fac_Eng_Univ_Tokyo-JP010785 | JEOL JMS-D-300 | EI-B | - | - | POSITIVE | MS |
MSBNK-GL_Sciences_Inc-GLS00108 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | POSITIVE | MS |
MSBNK-Osaka_MCHRI-MCH00002 | Voyager DE-PRO, Applied Biosys... | MALDI-TOF | - | - | POSITIVE | MS |
MSBNK-Osaka_MCHRI-MCH00007 | Voyager DE-PRO, Applied Biosys... | MALDI-TOF | - | - | POSITIVE | MS |
MSBNK-Osaka_MCHRI-MCH00017 | Voyager DE-PRO, Applied Biosys... | MALDI-TOF | - | - | POSITIVE | MS |
MSBNK-Osaka_Univ-OUF00239 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR100383 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS095201 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PT109520 | Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-45 V | - | POSITIVE | MS2 |