Massbank MS database records for Harmaline

Massbank ID Instrument Inst. type Collision energy Ion type Ion mode MS level
MSBNK-Washington_State_Univ-BML00090Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF10 ev[M-H]-NEGATIVEMS2
MSBNK-Washington_State_Univ-BML00086Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF20 ev[M-H]-NEGATIVEMS2
MSBNK-Washington_State_Univ-BML00094Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF40 ev[M-H]-NEGATIVEMS2
MSBNK-Washington_State_Univ-BML81351Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF--NEGATIVEMS
MSBNK-Washington_State_Univ-BML81353Agilent 1200 RRLC; Agilent 652...LC-APCI-QTOF--NEGATIVEMS
MSBNK-Washington_State_Univ-BML00065Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF10 ev[M+H]+POSITIVEMS2
MSBNK-Washington_State_Univ-BML00072Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF20 ev[M+H]+POSITIVEMS2
MSBNK-Washington_State_Univ-BML00079Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF40 ev[M+H]+POSITIVEMS2
MSBNK-Washington_State_Univ-BML81350Agilent 1200 RRLC; Agilent 652...LC-ESI-QTOF--POSITIVEMS
MSBNK-Washington_State_Univ-BML81352Agilent 1200 RRLC; Agilent 652...LC-APCI-QTOF--POSITIVEMS
MSBNK-Keio_Univ-KO001018API3000, Applied BiosystemsLC-ESI-QQ10 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO001019API3000, Applied BiosystemsLC-ESI-QQ20 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO001020API3000, Applied BiosystemsLC-ESI-QQ30 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO001021API3000, Applied BiosystemsLC-ESI-QQ40 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO001022API3000, Applied BiosystemsLC-ESI-QQ50 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO003098API3000, Applied BiosystemsLC-ESI-QQ10 V[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO003099API3000, Applied BiosystemsLC-ESI-QQ20 V[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO003100API3000, Applied BiosystemsLC-ESI-QQ30 V[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO003101API3000, Applied BiosystemsLC-ESI-QQ40 V[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO003102API3000, Applied BiosystemsLC-ESI-QQ50 V[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO008994LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT0.95[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO008997LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT0.60/0.60[M+H]+POSITIVEMS3
MSBNK-Keio_Univ-KO008995LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT0.80/0.65[M+H]+POSITIVEMS3
MSBNK-Keio_Univ-KO008996LC/MSD Trap XCT, Agilent Techn...LC-ESI-IT0.80/0.70[M+H]+POSITIVEMS3
MSBNK-Kazusa-KZ000213Pegasus III TOF-MS system, Lec...GC-EI-TOF--POSITIVEMS
MSBNK-RIKEN-PR010121Pegasus III TOF-MS system, Lec...GC-EI-TOF--POSITIVEMS
MSBNK-RIKEN_ReSpect-PS012501TQD, WatersLC-ESI-QQ10-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS012502TQD, WatersLC-ESI-QQ20-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS012503TQD, WatersLC-ESI-QQ30-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS012504TQD, WatersLC-ESI-QQ40-POSITIVEMS2
MSBNK-RIKEN-PR100517UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR100070UPLC Q-Tof Premier, WatersLC-ESI-QTOF30 V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR100069UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 V[M+H]+POSITIVEMS2
  logo