Massbank MS database records for Harmaline
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-Keio_Univ-KO008997 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.60/0.60 | [M+H]+ | POSITIVE | MS3 |
MSBNK-Keio_Univ-KO008995 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.80/0.65 | [M+H]+ | POSITIVE | MS3 |
MSBNK-Keio_Univ-KO008996 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.80/0.70 | [M+H]+ | POSITIVE | MS3 |
MSBNK-Keio_Univ-KO008994 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.95 | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS012501 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-Washington_State_Univ-BML00065 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 10 ev | [M+H]+ | POSITIVE | MS2 |
MSBNK-Washington_State_Univ-BML00090 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 10 ev | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001018 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO003098 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS012502 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-Washington_State_Univ-BML00072 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 20 ev | [M+H]+ | POSITIVE | MS2 |
MSBNK-Washington_State_Univ-BML00086 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 20 ev | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001019 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO003099 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS012503 | TQD, Waters | LC-ESI-QQ | 30 | - | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO001020 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO003100 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100070 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS012504 | TQD, Waters | LC-ESI-QQ | 40 | - | POSITIVE | MS2 |
MSBNK-Washington_State_Univ-BML00079 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 40 ev | [M+H]+ | POSITIVE | MS2 |
MSBNK-Washington_State_Univ-BML00094 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 40 ev | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001021 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO003101 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO001022 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO003102 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100069 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100517 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Kazusa-KZ000213 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR010121 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-Washington_State_Univ-BML81350 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | POSITIVE | MS |
MSBNK-Washington_State_Univ-BML81351 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | NEGATIVE | MS |
MSBNK-Washington_State_Univ-BML81352 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | POSITIVE | MS |
MSBNK-Washington_State_Univ-BML81353 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | NEGATIVE | MS |