Massbank MS database records for L-Histidine

Massbank ID Instrument Inst. type Collision energy Ion type Ion mode MS level
MSBNK-Antwerp_Univ-METOX_P100801_FB57Agilent 6530 QTOFLC-ESI-QTOF40 eV[M+H]+POSITIVEMS2
MSBNK-BGC_Munich-RP002001maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF10[M+H]+POSITIVEMS2
MSBNK-BGC_Munich-RP002002maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF20[M+H]+POSITIVEMS2
MSBNK-BGC_Munich-RP002003maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF40[M+H]+POSITIVEMS2
MSBNK-BGC_Munich-RP002011maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF10[M-H]-NEGATIVEMS2
MSBNK-BGC_Munich-RP002012maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF20[M-H]-NEGATIVEMS2
MSBNK-BGC_Munich-RP002013maXis plus UHR-ToF-MS, Bruker ...LC-ESI-QTOF40[M-H]-NEGATIVEMS2
MSBNK-IPB_Halle-PB000422API QSTAR Pulsar iLC-ESI-QTOF15 eV[M+H]+POSITIVEMS2
MSBNK-IPB_Halle-PB000423API QSTAR Pulsar iLC-ESI-QTOF25 eV[M+H]+POSITIVEMS2
MSBNK-IPB_Halle-PB000424API QSTAR Pulsar iLC-ESI-QTOF35 eV[M+H]+POSITIVEMS2
MSBNK-IPB_Halle-PB000425API QSTAR Pulsar iLC-ESI-QTOF45 eV[M+H]+POSITIVEMS2
MSBNK-Kazusa-KZ000045Pegasus III TOF-MS system, Lec...GC-EI-TOF--POSITIVEMS
MSBNK-Kazusa-KZ000155Pegasus III TOF-MS system, Lec...GC-EI-TOF--POSITIVEMS
MSBNK-Keio_Univ-KO000958API3000, Applied BiosystemsLC-ESI-QQ10 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO000959API3000, Applied BiosystemsLC-ESI-QQ20 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO000960API3000, Applied BiosystemsLC-ESI-QQ30 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO000961API3000, Applied BiosystemsLC-ESI-QQ40 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO000962API3000, Applied BiosystemsLC-ESI-QQ50 V[M-H]-NEGATIVEMS2
MSBNK-Keio_Univ-KO003054API3000, Applied BiosystemsLC-ESI-QQ10 V[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO003055API3000, Applied BiosystemsLC-ESI-QQ20 V[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO003056API3000, Applied BiosystemsLC-ESI-QQ30 V[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO003057API3000, Applied BiosystemsLC-ESI-QQ40 V[M+H]+POSITIVEMS2
MSBNK-Keio_Univ-KO003058API3000, Applied BiosystemsLC-ESI-QQ50 V[M+H]+POSITIVEMS2
MSBNK-Metabolon-MT000022LTQ XL, Thermo FinniganLC-ESI-IT40[M-H]-NEGATIVEMS2
MSBNK-NAIST-KNA00085LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFT35eV-POSITIVEMS
MSBNK-NAIST-KNA00356LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFT35eV-POSITIVEMS
MSBNK-NAIST-KNA00499LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFT35eV-NEGATIVEMS
MSBNK-NAIST-KNA00500LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFT35eV-NEGATIVEMS2
MSBNK-NAIST-KNA00740LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFT35eV-NEGATIVEMS
MSBNK-NAIST-KNA00741LTQ Orbitrap XL, Thermo Scient...LC-ESI-ITFT35eV-NEGATIVEMS2
MSBNK-Osaka_Univ-OUF00309Pegasus III TOF-MS system, Lec...GC-EI-TOF--POSITIVEMS
MSBNK-Osaka_Univ-OUF01016Agilent 7000B QqQMS, Agilent; ...GC-EI-QQ--POSITIVEMS
MSBNK-RIKEN-PR010033Pegasus III TOF-MS system, Lec...GC-EI-TOF--POSITIVEMS
MSBNK-RIKEN-PR030009CE-system connected to 6210 Ti...CE-ESI-TOF--POSITIVEMS
MSBNK-RIKEN-PR100027UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR100028UPLC Q-Tof Premier, WatersLC-ESI-QTOF30 V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR100321UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 V[M+H]+POSITIVEMS2
MSBNK-RIKEN-PR100495UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 V[M-H]-NEGATIVEMS2
MSBNK-RIKEN-PR100755UPLC Q-Tof Premier, WatersLC-ESI-QTOFRamp 5-60 V[M-H]-NEGATIVEMS2
MSBNK-RIKEN_ReSpect-PM000935API 2000 ESI-MS/MS system trip...LC-ESI-QQ18-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS005101TQD, WatersLC-ESI-QQ10-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS005102TQD, WatersLC-ESI-QQ20-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS005103TQD, WatersLC-ESI-QQ30-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS005107TQD, WatersLC-ESI-QQ10-NEGATIVEMS2
MSBNK-RIKEN_ReSpect-PS071801TQD, WatersLC-ESI-QQ10-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS071802TQD, WatersLC-ESI-QQ20-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS071803TQD, WatersLC-ESI-QQ30-POSITIVEMS2
MSBNK-RIKEN_ReSpect-PS071807TQD, WatersLC-ESI-QQ10-NEGATIVEMS2
  logo