Massbank MS database records for L-Homoserine
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-Antwerp_Univ-METOX_P100902_F638 | Agilent 6530 QTOF | LC-ESI-QTOF | 10 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Antwerp_Univ-METOX_P100902_EF88 | Agilent 6530 QTOF | LC-ESI-QTOF | 20 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Antwerp_Univ-METOX_P100902_FB57 | Agilent 6530 QTOF | LC-ESI-QTOF | 40 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003059 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003060 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003061 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003062 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-NAIST-KNA00554 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS |
MSBNK-NAIST-KNA00728 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS |
MSBNK-NAIST-KNA00555 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00729 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00730 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00141 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS |
MSBNK-NAIST-KNA00340 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS |
MSBNK-NAIST-KNA00142 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00143 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00341 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00342 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-Kazusa-KZ000228 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN_ReSpect-PT206280 | Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-45 V | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PT106280 | Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-45 V | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS062801 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS062802 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS062803 | TQD, Waters | LC-ESI-QQ | 30 | - | POSITIVE | MS2 |
MSBNK-RIKEN-PR100726 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR100294 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |