Massbank MS database records for L-Lysine
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-Antwerp_Univ-METOX_P100301_EF88 | Agilent 6530 QTOF | LC-ESI-QTOF | 20 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Antwerp_Univ-METOX_P100301_FB57 | Agilent 6530 QTOF | LC-ESI-QTOF | 40 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Osaka_Univ-OUF01014 | Agilent 7000B QqQMS, Agilent; ... | GC-EI-QQ | - | - | POSITIVE | MS |
MSBNK-RIKEN_ReSpect-PM000932 | API 2000 ESI-MS/MS system trip... | LC-ESI-QQ | 22 | - | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO001265 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001266 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001267 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001268 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001269 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO003282 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003283 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003284 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003285 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003286 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR030012 | CE-system connected to 6210 Ti... | CE-ESI-TOF | - | - | POSITIVE | MS |
MSBNK-GL_Sciences_Inc-GLS00119 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | POSITIVE | MS |
MSBNK-GL_Sciences_Inc-GLS00120 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | POSITIVE | MS |
MSBNK-MetaboLights-ML004701 | LTQ Orbitrap Velos Thermo Scie... | LC-ESI-ITFT | 50 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-NAIST-KNA00069 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS |
MSBNK-NAIST-KNA00070 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00071 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00072 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00256 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS |
MSBNK-NAIST-KNA00258 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP001101 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 10 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP001102 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 20 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP001103 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 40 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP001112 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 20 | [M-H]- | NEGATIVE | MS2 |
MSBNK-Kazusa-KZ000234 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-Osaka_Univ-OUF00315 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR010062 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR100167 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100322 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100756 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |