Massbank MS database records for Luteolin
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-BS-BS003098 | Bruker impact HD | LC-ESI-QTOF | - | - | NEGATIVE | MS |
MSBNK-RIKEN-PR020016 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | 5.0 V | - | POSITIVE | MS |
MSBNK-Univ_Toyama-TY000143 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | POSITIVE | MS |
MSBNK-Univ_Toyama-TY000144 | LCMS-IT-TOF | LC-ESI-ITTOF | - | - | NEGATIVE | MS |
MSBNK-Washington_State_Univ-BML81650 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | POSITIVE | MS |
MSBNK-Washington_State_Univ-BML81651 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | NEGATIVE | MS |
MSBNK-Washington_State_Univ-BML81652 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | POSITIVE | MS |
MSBNK-Washington_State_Univ-BML81653 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | NEGATIVE | MS |
MSBNK-BGC_Munich-RP004801 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 10 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP004802 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 20 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP004803 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 40 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BS-BS003099 | Bruker impact HD | LC-ESI-QTOF | 30 eV | [M-H]- | NEGATIVE | MS2 |
MSBNK-IPB_Halle-PB000741 | API QSTAR Pulsar i | LC-ESI-QTOF | 15 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-IPB_Halle-PB000742 | API QSTAR Pulsar i | LC-ESI-QTOF | 25 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-IPB_Halle-PB000743 | API QSTAR Pulsar i | LC-ESI-QTOF | 40 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-IPB_Halle-PB000744 | API QSTAR Pulsar i | LC-ESI-QTOF | 55 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-IPB_Halle-PN000112 | micrOTOF-Q | ESI-TOF | 25 eV | [M-H]- | NEGATIVE | MS2 |
MSBNK-IPB_Halle-PN000113 | micrOTOF-Q | ESI-TOF | 15 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR040034 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 eV | - | NEGATIVE | MS2 |
MSBNK-RIKEN-PR040035 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | 30 eV | - | POSITIVE | MS2 |
MSBNK-RIKEN-PR040036 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 eV | - | POSITIVE | MS2 |
MSBNK-RIKEN-PR100230 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100231 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100643 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR100644 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | 30 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR302214 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302219 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302224 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302229 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302234 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302239 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302244 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302249 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302254 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302259 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302264 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR302269 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR305851 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305858 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305864 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305870 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305877 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305884 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305890 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305895 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305902 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305909 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305915 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR305922 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR310942 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PM000420 | Agilent (Waldbronn, Germany) M... | LC-ESI-QQ | -35 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS040401 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS040402 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS040403 | TQD, Waters | LC-ESI-QQ | 30 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS040404 | TQD, Waters | LC-ESI-QQ | 40 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS040407 | TQD, Waters | LC-ESI-QQ | 10 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS040408 | TQD, Waters | LC-ESI-QQ | 20 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS040409 | TQD, Waters | LC-ESI-QQ | 30 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS040410 | TQD, Waters | LC-ESI-QQ | 40 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS040411 | TQD, Waters | LC-ESI-QQ | 50 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PT104040 | Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-45 V | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PT104043 | Q-Tof Premier, Waters | LC-ESI-QTOF | 30 V | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PT204040 | Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-45 V | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PT204043 | Q-Tof Premier, Waters | LC-ESI-QTOF | 30 V | - | NEGATIVE | MS2 |
MSBNK-Washington_State_Univ-BML00104 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 10 ev | [M+H]+ | POSITIVE | MS2 |
MSBNK-Washington_State_Univ-BML00116 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 20 ev | [M+H]+ | POSITIVE | MS2 |
MSBNK-Washington_State_Univ-BML00128 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 40 ev | [M+H]+ | POSITIVE | MS2 |
MSBNK-Washington_State_Univ-BML00136 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 10 ev | [M-H]- | NEGATIVE | MS2 |
MSBNK-Washington_State_Univ-BML00144 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 20 ev | [M-H]- | NEGATIVE | MS2 |
MSBNK-Washington_State_Univ-BML00151 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | 40 ev | [M-H]- | NEGATIVE | MS2 |