Massbank MS database records for Metformin
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-ACES_SU-AS000120 | QExactive Orbitrap HF-X (Therm... | LC-APCI-QFT | Ramp 20%-70% (nominal) | - | POSITIVE | MS2 |
MSBNK-Eawag-EA255001 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 35 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255002 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 15 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255003 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 30 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255004 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 45 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255005 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 60 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255006 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 75 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255007 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 90 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255008 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 15 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255009 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 30 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255010 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 45 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255011 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 60 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255012 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 75 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255013 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 90 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Eawag-EA255014 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 35 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UF412401 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 55 (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UF412402 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 80 (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UF412403 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 35 (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UF412404 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 55 (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Waters-WA000492 | ZQ, Waters | LC-ESI-Q | - | - | POSITIVE | MS |
MSBNK-Waters-WA000493 | ZQ, Waters | LC-ESI-Q | - | - | POSITIVE | MS |
MSBNK-Waters-WA000494 | ZQ, Waters | LC-ESI-Q | - | - | POSITIVE | MS |
MSBNK-Waters-WA000495 | ZQ, Waters | LC-ESI-Q | - | - | POSITIVE | MS |
MSBNK-ACES_SU-AS000190 | QExactive Orbitrap HF-X (Therm... | LC-ESI-QFT | Ramp 20%-70% (nominal) | - | POSITIVE | MS2 |
MSBNK-CASMI_2016-SM867803 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | 35 (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003372 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003373 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003374 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003375 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003376 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS002201 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS002202 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS002203 | TQD, Waters | LC-ESI-QQ | 30 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS002204 | TQD, Waters | LC-ESI-QQ | 40 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS002205 | TQD, Waters | LC-ESI-QQ | 50 | - | POSITIVE | MS2 |
MSBNK-Athens_Univ-AU112701 | Bruker maXis Impact | LC-ESI-QTOF | Ramp 15.5-23.2 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Athens_Univ-AU112702 | Bruker maXis Impact | LC-ESI-QTOF | 20 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-Athens_Univ-AU112703 | Bruker maXis Impact | LC-ESI-QTOF | 10 eV | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016405 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 40 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016406 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 20 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016407 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 60 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016408 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 130 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016409 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 80 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016410 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 30 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016411 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 10 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016412 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 100 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016413 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 40 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016414 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 150 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016415 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 70 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016416 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 50 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016417 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 120 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016418 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 90 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016419 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 140 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BAFG-CSL23111016420 | TripleTOF 6600 SCIEX | LC-ESI-QTOF | 110 | [M+H]+ | POSITIVE | MS2 |
MSBNK-Env_Anal_Chem_U_Tuebingen-TUE00511 | 6550 Q-TOF (Agilent Technologi... | LC-ESI-QTOF | 10.0V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Env_Anal_Chem_U_Tuebingen-TUE00512 | 6550 Q-TOF (Agilent Technologi... | LC-ESI-QTOF | 20.0V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Env_Anal_Chem_U_Tuebingen-TUE00513 | 6550 Q-TOF (Agilent Technologi... | LC-ESI-QTOF | 40.0V | [M+H]+ | POSITIVE | MS2 |