Massbank MS database records for Pantothenic acid
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-Keio_Univ-KO001605 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001606 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001607 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001608 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001609 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-LCSB-LU087051 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 15 | [M-H]- | NEGATIVE | MS2 |
MSBNK-LCSB-LU087052 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 30 | [M-H]- | NEGATIVE | MS2 |
MSBNK-LCSB-LU087053 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 45 | [M-H]- | NEGATIVE | MS2 |
MSBNK-LCSB-LU087054 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 60 | [M-H]- | NEGATIVE | MS2 |
MSBNK-LCSB-LU087055 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 75 | [M-H]- | NEGATIVE | MS2 |
MSBNK-LCSB-LU087056 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 90 | [M-H]- | NEGATIVE | MS2 |
MSBNK-Metabolon-MT000131 | LTQ XL, Thermo Finnigan | LC-ESI-IT | 40 | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR100728 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR100858 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Kazusa-KZ000066 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-Keio_Univ-KO003695 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003696 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003697 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003698 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003699 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO009182 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.7 | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO009183 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.60/0.50 | [M+H]+ | POSITIVE | MS3 |
MSBNK-Keio_Univ-KO009184 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.70/0.50 | [M+H]+ | POSITIVE | MS3 |
MSBNK-Keio_Univ-KO009185 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.60/0.50/0.40 | [M+H]+ | POSITIVE | MS4 |
MSBNK-Keio_Univ-KO009186 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.60/0.50/0.40 | [M+H]+ | POSITIVE | MS4 |
MSBNK-LCSB-LU087001 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 15 | [M+H]+ | POSITIVE | MS2 |
MSBNK-LCSB-LU087002 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 30 | [M+H]+ | POSITIVE | MS2 |
MSBNK-LCSB-LU087003 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 45 | [M+H]+ | POSITIVE | MS2 |
MSBNK-LCSB-LU087004 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 60 | [M+H]+ | POSITIVE | MS2 |
MSBNK-LCSB-LU087005 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 75 | [M+H]+ | POSITIVE | MS2 |
MSBNK-LCSB-LU087006 | Q Exactive Orbitrap (Thermo Sc... | LC-ESI-QFT | 90 | [M+H]+ | POSITIVE | MS2 |
MSBNK-Osaka_Univ-OUF00414 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR010017 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR010018 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR100040 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100041 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100295 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100400 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |