Massbank MS database records for S-Lactoylglutathione
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-Keio_Univ-KO001290 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001291 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001292 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001293 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001294 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO003297 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003298 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003299 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003300 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO003301 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO009024 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.55 | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO009025 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.55/0.50 | [M+H]+ | POSITIVE | MS3 |
MSBNK-Keio_Univ-KO009026 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.75/0.70 | [M+H]+ | POSITIVE | MS3 |
MSBNK-Keio_Univ-KO009029 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.75/0.55/0.50 | [M+H]+ | POSITIVE | MS4 |
MSBNK-Keio_Univ-KO009028 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.75/0.55/0.55 | [M+H]+ | POSITIVE | MS4 |
MSBNK-Keio_Univ-KO009030 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.75/0.65/0.45 | [M+H]+ | POSITIVE | MS4 |
MSBNK-Keio_Univ-KO009027 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.75/0.65/0.60 | [M+H]+ | POSITIVE | MS4 |
MSBNK-RIKEN_ReSpect-PS068301 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS068302 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS068303 | TQD, Waters | LC-ESI-QQ | 30 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS068305 | TQD, Waters | LC-ESI-QQ | 50 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS068306 | TQD, Waters | LC-ESI-QQ | 60 | - | POSITIVE | MS2 |
MSBNK-RIKEN-PR100746 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR100314 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |