Massbank MS database records for Sinapic acid
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-Keio_Univ-KO001822 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001823 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001824 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001825 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO001826 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Fac_Eng_Univ_Tokyo-JP007240 | HITACHI M-52 | EI-B | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR307062 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307065 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307068 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307071 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307073 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307075 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307078 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307081 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307083 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307086 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307089 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR307092 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR309001 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR303342 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303345 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303348 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303351 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303354 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303357 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303360 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303363 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303366 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303369 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303372 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR303375 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR311176 | LC, Waters Acquity UPLC System... | LC-ESI-QTOF | 6V | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP017411 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 10 | [M-H]- | NEGATIVE | MS2 |
MSBNK-BGC_Munich-RP017412 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 20 | [M-H]- | NEGATIVE | MS2 |
MSBNK-BGC_Munich-RP017413 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 40 | [M-H]- | NEGATIVE | MS2 |
MSBNK-BGC_Munich-RP017401 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 10 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP017402 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 20 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP017403 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 40 | [M+H]+ | POSITIVE | MS2 |
MSBNK-Kazusa-KZ000073 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-Osaka_Univ-OUF00459 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR010129 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR010130 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN_ReSpect-PS045307 | TQD, Waters | LC-ESI-QQ | 10 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS108807 | TQD, Waters | LC-ESI-QQ | 10 | - | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS015601 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS045301 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS108801 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS015602 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS045302 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS108802 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-RIKEN-PR100527 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR100984 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN-PR100093 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR101042 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR020014 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | 5.0 V | - | POSITIVE | MS |
MSBNK-Osaka_MCHRI-MCH00014 | Voyager DE-PRO, Applied Biosys... | MALDI-TOF | - | - | NEGATIVE | MS |
MSBNK-Osaka_MCHRI-MCH00015 | Voyager DE-PRO, Applied Biosys... | MALDI-TOF | - | - | POSITIVE | MS |