Massbank MS database records for Uridine
Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|
MSBNK-Keio_Univ-KO009307 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.5 | [M+H]+ | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO009308 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | 0.50/0.50 | [M+H]+ | POSITIVE | MS3 |
MSBNK-BGC_Munich-RP031401 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 10 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP031411 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 10 | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS036501 | TQD, Waters | LC-ESI-QQ | 10 | - | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO004246 | API3000, Applied Biosystems | LC-ESI-QQ | 10 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP031402 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 20 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP031412 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 20 | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS036502 | TQD, Waters | LC-ESI-QQ | 20 | - | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO004247 | API3000, Applied Biosystems | LC-ESI-QQ | 20 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS036503 | TQD, Waters | LC-ESI-QQ | 30 | - | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO004248 | API3000, Applied Biosystems | LC-ESI-QQ | 30 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-NAIST-KNA00113 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS |
MSBNK-NAIST-KNA00114 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00115 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00116 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00280 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS |
MSBNK-NAIST-KNA00281 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00282 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00283 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | POSITIVE | MS2 |
MSBNK-NAIST-KNA00515 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS |
MSBNK-NAIST-KNA00516 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00517 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00518 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00676 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS |
MSBNK-NAIST-KNA00677 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00678 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-NAIST-KNA00679 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | 35eV | - | NEGATIVE | MS2 |
MSBNK-BGC_Munich-RP031403 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 40 | [M+H]+ | POSITIVE | MS2 |
MSBNK-BGC_Munich-RP031413 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | 40 | [M-H]- | NEGATIVE | MS2 |
MSBNK-Metabolon-MT000120 | LTQ XL, Thermo Finnigan | LC-ESI-IT | 40 | [M-H]- | NEGATIVE | MS2 |
MSBNK-RIKEN_ReSpect-PS036504 | TQD, Waters | LC-ESI-QQ | 40 | - | POSITIVE | MS2 |
MSBNK-Keio_Univ-KO004249 | API3000, Applied Biosystems | LC-ESI-QQ | 40 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-MetaboLights-ML005751 | LTQ Orbitrap Velos Thermo Scie... | LC-ESI-ITFT | 50 % (nominal) | [M-H]- | NEGATIVE | MS2 |
MSBNK-Keio_Univ-KO004250 | API3000, Applied Biosystems | LC-ESI-QQ | 50 V | [M+H]+ | POSITIVE | MS2 |
MSBNK-RIKEN-PR100615 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | Ramp 5-60 V | [M-H]- | NEGATIVE | MS2 |
MSBNK-Kazusa-KZ000273 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-Osaka_Univ-OUF00486 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-Osaka_Univ-OUF00487 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-RIKEN-PR010029 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | POSITIVE | MS |
MSBNK-Washington_State_Univ-BML82300 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | POSITIVE | MS |
MSBNK-Washington_State_Univ-BML82301 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | NEGATIVE | MS |