Metadata details for analysis AN001515 | |
---|---|
Study ID | ST000923 |
Analysis ID | AN001515 |
Study Title | Longitudinal Metabolomics of the Human Microbiome in Inflammatory Bowel Disease |
Institute | Broad Institute of MIT and Harvard |
Species | Homo sapiens |
Ion_mode | NEGATIVE |
MS type | ESI |
MS Instrument Name | Thermo Q Exactive Orbitrap |
MS Instrument Type | Orbitrap |
Chromatography Instrument Name | Shimadzu Nexera X2 |
Chromatography Type | Reversed phase |
Chromatography Column | Waters ACQUITY UPLC BEH C18 |
Solvent A | 100% water; 0.01% formic acid |
Solvent B | 100% acetonitrile; 0.01% acetic acid |
Gradient | The column was eluted isocratically at a flow rate of 450 µL/min with 20% A for 3 minutes followed by a linear gradient to 100% B over 12 minutes. |
Flow rate | 450 µL/min |
Column Temperature | |
Retention time units | Minutes |