Metadata details for analysis AN003914
Study IDST002402
Analysis IDAN003914
Study TitleFour-dimensional trapped ion mobility spectrometry lipidomics for high throughput clinical profiling of human blood samples
InstituteUniversity Medical Center of Mainz
SpeciesHomo sapiens
Ion_modeNEGATIVE
MS typeESI
MS Instrument NameBruker timsTOF
MS Instrument TypetimsTOF
Chromatography Instrument NameBruker UHPLC
Chromatography TypeReversed phase
Chromatography ColumnPhenomenex Luna Omega C18 (100 x 2.1mm,1.6um)
Solvent A50% methanol/50% water; 0.1% formic acid; 7.5 mM ammonium formate, 0.1% triethylamine
Solvent B20% methanol/80% isopropanol; 0.1% formic acid; 7.5 mM ammonium formate; 0.1% triethylamine
GradientThe LC method consisted of a 20 min runtime with the following gradient: T0 to T1 – mobile phase A at 60% and mobile phase B at 40% which was then elevated to 90% mobile phase B and 10% mobile phase by T16 and up to 99% mobile phase B by T16.5 and then escalated back to 40% mobile phase B by T20
Flow rate200 µl/min
Column Temperature45
Retention time unitsMinutes