Return to study ST000098 main page

MB Sample ID: SA005499

Local Sample ID:HSP_ms2_pos.raw
Subject ID:SU000117
Subject Type:Invertebrate
Subject Species:Caenorhabditis elegans
Taxonomy ID:6239
Genotype Strain:N2
Species Group:Invertebrate

Select appropriate tab below to view additional metadata details:


Analysis:

MB Sample ID:SA005499
Analysis ID:AN000162
Laboratory Name:Arthur Edison
Analysis Type:NMR
Analysis Comments:Carbon 1D dataset was all collected using the custom 1.5 mm HTS prob
Software Version:VNMRJ
Operator Name:Chaevien Clendinen
Randomization Order:NMR/Processed
Data Format:Varian FID
Chromatography ID:CH000112
Num Factors:3
  
MB Sample ID:SA005499
Analysis ID:AN000161
Laboratory Name:Arthur Edison
Analysis Type:NMR
Analysis Comments:HSQC-TOCSY dataset was collected using the custom 1.5 mm HTS prob
Software Version:VNMRJ
Operator Name:Chaevien Clendinen
Randomization Order:NMR/Processed
Data Format:Varian FID
Chromatography ID:CH000112
Num Factors:3
  
MB Sample ID:SA005499
Analysis ID:AN000157
Laboratory Name:Timothy Garrett
Analysis Type:MS
Analysis Comments:Samples were analyzed using a mass range of 70-1000 in positive and negative ionization modes, externally calibrated, using a Thermo Scientific Q-Exactive Orbitrap mass spectrometer equipped with a Dionex UltiMate 3000 RS autosampler and pump. The Q-Exactive was equipped with a Heated Electrospray Ionization (HESI) source which operated at a spray temperature of 350 ?C, a spray voltage of 3.5 kV, and sheath and auxiliary gas flow rates of 50 and 10 arbitrary units, respectively. The capillary temperature was held at 325 ?C, and the S-lens RF Level was set to 40%. The FR resolution was set to 70,000 at m/z 200. The accuracy achieved was routinely less than 1.5 ppm. In addition to full MS, data-dependent MS/MS was performed on the 10 most abundance peaks with an exclusion period of 10 seconds (40 normalized collision energy). Fractionation was performed using a Dionex UltiMate 3000 fraction collector by triggering every 30 seconds.
Instrument Name:Thermo Scientific Q-Exactive
Operator Name:Timothy Garrett
Detector Type:Thermo Scientific Q-Exactive Orbitrap/MS Positive
Chromatography ID:CH000112
Num Factors:3
  
MB Sample ID:SA005499
Analysis ID:AN000160
Laboratory Name:Arthur Edison
Analysis Type:NMR
Analysis Comments:HSQC dataset was collected using the custom 1.5 mm HTS probe
Software Version:VNMRJ
Operator Name:Chaevien Clendinen
Randomization Order:NMR/Processed
Data Format:Varian FID
Chromatography ID:CH000112
Num Factors:3
  
MB Sample ID:SA005499
Analysis ID:AN000159
Laboratory Name:Timothy Garrett
Analysis Type:MS
Analysis Comments:Samples were analyzed using a mass range of 70-1000 in positive and negative ionization modes, externally calibrated, using a Thermo Scientific Q-Exactive Orbitrap mass spectrometer equipped with a Dionex UltiMate 3000 RS autosampler and pump. The Q-Exactive was equipped with a Heated Electrospray Ionization (HESI) source which operated at a spray temperature of 350 ?C, a spray voltage of 3.5 kV, and sheath and auxiliary gas flow rates of 50 and 10 arbitrary units, respectively. The capillary temperature was held at 325 ?C, and the S-lens RF Level was set to 40%. The FR resolution was set to 70,000 at m/z 200. The accuracy achieved was routinely less than 1.5 ppm. In addition to full MS, data-dependent MS/MS was performed on the 10 most abundance peaks with an exclusion period of 10 seconds (40 normalized collision energy). Fractionation was performed using a Dionex UltiMate 3000 fraction collector by triggering every 30 seconds.
Instrument Name:Thermo Scientific Q-Exactive
Operator Name:Timothy Garrett
Detector Type:Thermo Scientific Q-Exactive Orbitrap/MS2 Negative
Chromatography ID:CH000112
Num Factors:3
  
MB Sample ID:SA005499
Analysis ID:AN000158
Laboratory Name:Timothy Garrett
Analysis Type:MS
Analysis Comments:Samples were analyzed using a mass range of 70-1000 in positive and negative ionization modes, externally calibrated, using a Thermo Scientific Q-Exactive Orbitrap mass spectrometer equipped with a Dionex UltiMate 3000 RS autosampler and pump. The Q-Exactive was equipped with a Heated Electrospray Ionization (HESI) source which operated at a spray temperature of 350 ?C, a spray voltage of 3.5 kV, and sheath and auxiliary gas flow rates of 50 and 10 arbitrary units, respectively. The capillary temperature was held at 325 ?C, and the S-lens RF Level was set to 40%. The FR resolution was set to 70,000 at m/z 200. The accuracy achieved was routinely less than 1.5 ppm. In addition to full MS, data-dependent MS/MS was performed on the 10 most abundance peaks with an exclusion period of 10 seconds (40 normalized collision energy). Fractionation was performed using a Dionex UltiMate 3000 fraction collector by triggering every 30 seconds.
Instrument Name:Thermo Scientific Q-Exactive
Operator Name:Timothy Garrett
Detector Type:Thermo Scientific Q-Exactive Orbitrap/MS2 Positive
Chromatography ID:CH000112
Num Factors:3
  logo