Summary of Study ST000882
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000611. The data can be accessed directly via it's Project DOI: 10.21228/M8XQ41 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST000882 |
Study Title | Untargeted metabolomics data of leprosy patients with type 1 reaction |
Study Type | Untargeted MS qualitative analysis in retrospective serum samples of leprosy patients with type 1 reaction |
Study Summary | Untargeted metabolomics-based analyses of sera from 7 patients with and 9 without T1R were conducted via liquid chromatography–mass spectrometry. |
Institute | Colorado State University |
Department | Department of Microbiology, Immunology, and Pathology |
Laboratory | Belisle |
Last Name | Silva |
First Name | Carlos |
Address | Rampart Road, 1682 Campus Delivery |
cadriano@rams.colostate.edu | |
Phone | 9702154962 |
Submit Date | 2017-06-19 |
Num Groups | 2 |
Total Subjects | 16 |
Num Males | 5 |
Num Females | 11 |
Study Comments | 2 groups (first group was leprosy patients with type 1 reaction, N=9; and second group was leprosy patients without type 1 reaction, N=7) 5 males (3 were leprosy patients with type 1 reaction and 2 were leprosy patients without type 1 reaction), 11 females (4 were leprosy patients with type 1 reaction and 7 were leprosy patients without type 1 reaction). For this study we used retrospective sera samples. |
Publications | J Infect Dis. 2017 Feb 1;215(3):431-439. doi: 10.1093/infdis/jiw541. |
Raw Data Available | Yes |
Raw Data File Type(s) | d |
Analysis Type Detail | LC-MS |
Release Date | 2017-06-19 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN001438 | AN001439 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Agilent 1290 | Agilent 1290 |
Column | Waters Xbridge BEH C18 XP (100 x 2.1mm,2.5um) | Waters Xbridge BEH C18 XP (100 x 2.1mm,2.5um) |
MS Type | ESI | ESI |
MS instrument type | TOF | TOF |
MS instrument name | Agilent 6224 TOF | Agilent 6224 TOF |
Ion Mode | NEGATIVE | POSITIVE |
Units | Peak area | Peak area |
MS:
MS ID: | MS001328 |
Analysis ID: | AN001438 |
Instrument Name: | Agilent 6224 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
Ion Mode: | NEGATIVE |
Capillary Voltage: | 2.8kV |
Dry Gas Flow: | 5 L/min |
Dry Gas Temp: | 310C |
Fragment Voltage: | 120V |
Nebulizer: | 20 psig |
Scanning Range: | 2 spectra per second |
Skimmer Voltage: | 50V |
MS ID: | MS001329 |
Analysis ID: | AN001439 |
Instrument Name: | Agilent 6224 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
Ion Mode: | POSITIVE |
Capillary Voltage: | 4.0kV |
Dry Gas Flow: | 5 L/min |
Dry Gas Temp: | 310C |
Fragment Voltage: | 120V |
Nebulizer: | 20 psig |
Scanning Range: | 2 spectra per second |
Skimmer Voltage: | 50V |