Summary of Study ST003238

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002013. The data can be accessed directly via it's Project DOI: 10.21228/M8DJ7S This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003238
Study TitleLipidomic analysis of serum from Gclc WT and whole-body Gclc KO mice.
Study SummaryWe found decreased triglycerides in the serum of whole-body deletion of Gclc mice compared to wildtype mice.
Institute
University of Rochester Medical Center
Last NameHarris
First NameIsaac
Address601 Elmwood Ave, Rochester, New York, 14642-0001, USA
Emailisaac_harris@urmc.rochester.edu
Phone8572348624
Submit Date2024-05-29
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-06-07
Release Version1
Isaac Harris Isaac Harris
https://dx.doi.org/10.21228/M8DJ7S
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005303 AN005304
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Brownlee SPP C18 (75 x 2.1mm, 2.7um) Brownlee SPP C18 (75 x 2.1mm, 2.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Normalized to the median value of total lipid signals Normalized to the median value of total lipid signals

MS:

MS ID:MS005033
Analysis ID:AN005303
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The scan range was from m/z 250–1500, resolution was 60,000 for MS, and 30,000 for DDMS2 (top 10), and the AGC target was 3E6 for full MS and 1E5 for DDMS2, allowing ions to accumulate for up to 200 ms for MS and 50 ms for MS/MS. For MS/MS, the following settings are used: isolation window width 1.2 m/z with an offset of 0.5 m/z, stepped NCE at 10, 15, and 25 a.u., minimum AGC 5E2, and dynamic exclusion of previously sampled peaks for 8 s.
Ion Mode:POSITIVE
  
MS ID:MS005034
Analysis ID:AN005304
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The scan range was from m/z 250–1500, resolution was 60,000 for MS, and 30,000 for DDMS2 (top 10), and the AGC target was 3E6 for full MS and 1E5 for DDMS2, allowing ions to accumulate for up to 200 ms for MS and 50 ms for MS/MS. For MS/MS, the following settings are used: isolation window width 1.2 m/z with an offset of 0.5 m/z, stepped NCE at 10, 15, and 25 a.u., minimum AGC 5E2, and dynamic exclusion of previously sampled peaks for 8 s.