Summary of Study ST001722
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001104. The data can be accessed directly via it's Project DOI: 10.21228/M80M6C This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001722 |
Study Title | The effects of birth weight and breeding value for protein deposition on the plasma metabolome in growing pigs (part-I) |
Study Summary | An experiment was conducted with growing pigs, to determine the effects of birth weight (BiW) and estimated breeding value for protein deposition (EBV) on the metabolomic profile in plasma samples collected under different dietary regimens: protein adequate (A) or protein restricted (R, 70% of A). |
Institute | Aarhus University |
Department | Animal Science |
Laboratory | Metabolomics LC-MS platform Aarhus University Foulum |
Last Name | Hedemann |
First Name | Mette |
Address | Blichers Alle 20, Tjele, -, 8830, Denmark |
Mette.Hedemann@anis.au.dk | |
Phone | 51448783 |
Submit Date | 2021-03-12 |
Total Subjects | 40 |
Num Males | 40 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzXML |
Analysis Type Detail | LC-MS |
Release Date | 2021-03-31 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002806 |
---|---|
Analysis type | MS |
Chromatography type | Reversed phase |
Chromatography system | Thermo Dionex Ultimate 3000 RS |
Column | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
MS Type | ESI |
MS instrument type | QTOF |
MS instrument name | Bruker Impact HD |
Ion Mode | NEGATIVE |
Units | peak area |
MS:
MS ID: | MS002601 |
Analysis ID: | AN002806 |
Instrument Name: | Bruker Impact HD |
Instrument Type: | QTOF |
MS Type: | ESI |
MS Comments: | The eluent was introduced into the mass spectrometer by electrospray ionization, with capillary set in the positive and negative mode to 4500 and 3600 V, respectively. End-plate offset voltage was set to 500 V. Nitrogen was used as both nebulizer and drying gas with a gas pressure of 1.8 bar. Drying gas temperature and flow were 200 °C and 8.0 L/min, respectively. Spectra were acquired over the scan range of 50−1000 m/z. A solution of lithium formate clusters (5 mM) (water/isopropanol/formic acid in a 50:50:0.2 v/v/v ratio) was injected prior to each chromatographic run as an external calibrant. |
Ion Mode: | NEGATIVE |