Return to study ST001158 main page

MB Sample ID: SA080342

Local Sample ID:JHOP-05731
Subject ID:SU001223
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001223
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Gender:Male and female

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
JHOP-05731SA080342FL012312FecesSample
JHOP-05731SA080342FL012312Angiotensin IITreatment

Collection:

Collection ID:CO001217
Collection Summary:Feces
Collection Protocol Filename:Sample_Collection-Feces_Pluznick.pdf
Sample Type:Feces
Storage Conditions:-80℃

Treatment:

Treatment ID:TR001238
Treatment Summary:Six week old C57BL/6 conventional (mice with gut microbiota; conv, n=6) and germ-free (mice without gut microbiota; GF, n=6) mice were infused with angiotensin-II (AngII) for 4 weeks (400ng.kg-1.min-1; Alzet 1004). In parallel control groups, conv (n=6) and GF (n=6) mice received saline via minipumps.
Treatment Protocol Filename:Treatment_Protocol__Pluznick.pdf

Sample Preparation:

Sampleprep ID:SP001231
Sampleprep Summary:Samples were prepared using the automated MicroLab STAR® system from Hamilton Company. Several recovery standards were added prior to the first step in the extraction process for QC purposes. The resulting extract was divided into five fractions: two for analysis by two separate reverse phase (RP)/UPLC-MS/MS methods with positive ion mode electrospray ionization (ESI), one for analysis by RP/UPLC-MS/MS with negative ion mode ESI, one for analysis by HILIC/UPLC-MS/MS with negative ion mode ESI, and one sample was reserved for backup. Samples were placed briefly on a TurboVap® (Zymark) to remove the organic solvent. The sample extracts were stored overnight under nitrogen before preparation for analysis.
Sampleprep Protocol Filename:Sample_Preparation_Pluznick.pdf

Combined analysis:

Analysis ID AN001916
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Scientific Q-Exactive high resolution/accurate mass spectrometer
Column C18
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE
Units Peaks area

Chromatography:

Chromatography ID:CH001389
Methods Filename:Ultrahigh_Performance_LC_Method_Pluznick.pdf
Instrument Name:Thermo Scientific Q-Exactive high resolution/accurate mass spectrometer
Column Name:C18
Chromatography Type:Reversed phase

MS:

MS ID:MS001772
Analysis ID:AN001916
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:None
Ion Mode:NEGATIVE
  logo