Return to study ST001481 main page

MB Sample ID: SA125061

Local Sample ID:AC2 37
Subject ID:SU001555
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:Ndufs4, https://www.jax.org/strai n/02705 8
Age Or Age Range:45-50 days
Gender:Male
Animal Animal Supplier:Jackson Laboratory (ME, USA)
Animal Light Cycle:12:12 h
Animal Feed:Rodent Breeder, Cat. #RM1845, LabChef, Nutritionhub
Animal Water:ad libitum

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001555
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:Ndufs4, https://www.jax.org/strai n/02705 8
Age Or Age Range:45-50 days
Gender:Male
Animal Animal Supplier:Jackson Laboratory (ME, USA)
Animal Light Cycle:12:12 h
Animal Feed:Rodent Breeder, Cat. #RM1845, LabChef, Nutritionhub
Animal Water:ad libitum

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
AC2 37SA125061FL015333WTGenotype

Collection:

Collection ID:CO001550
Collection Summary:Mice were euthanized between postnatal day (P) 45-50 via cervical dislocation at the same time of day (8:00-9:00 AM) after overnight (12-h) fasting. The brain was removed and rinsed with saline solution (SABAX PBS; 0.9% NaCl (w/v), #7634, Adcock Ingram) to remove surrounding blood. The brain regions of interest, namely the anterior cortex (AC), brainstem (BS), cerebellum (CB) and olfactory bulbs (OB), were then dissected, snap-frozen in liquid nitrogen (within 15 minutes postmortem) and stored at − 80°C until used.
Sample Type:Brain

Treatment:

Treatment ID:TR001570
Treatment Summary:The animals did not receive any treatment

Sample Preparation:

Sampleprep ID:SP001563
Sampleprep Summary:Brain regions were homogenized in the presence of internal standards using a vibration mill. Metabolite extraction was achieved using a modified monophasic Bligh–Dyer extraction method with a solvent ratio of 3:1:1 (methanol:water:chloroform).
Sampleprep Protocol Filename:GC_sample_prep_protocol.pdf
Data_processing_method.pdf

Combined analysis:

Analysis ID AN002458
Analysis type MS
Chromatography type GC
Chromatography system Agilent 7890A
Column Restek Rtx-5Sil (30m x 0.25mm,0.25um)
MS Type EI
MS instrument type GC-TOF
MS instrument name Leco Pegasus HT TOF
Ion Mode POSITIVE
Units Area

Chromatography:

Chromatography ID:CH001800
Instrument Name:Agilent 7890A
Column Name:Restek Rtx-5Sil (30m x 0.25mm,0.25um)
Chromatography Type:GC

MS:

MS ID:MS002278
Analysis ID:AN002458
Instrument Name:Leco Pegasus HT TOF
Instrument Type:GC-TOF
MS Type:EI
MS Comments:The LECO Corporation ChromaTOF® software (v 4.5x) was used for data acquisition and extraction. This included automatic baseline removal via the “spanning” tracking method (offset of 1; just above the noise) and auto smoothing, with the software’s Statistical Compare feature used to align peaks. Spectral matching was done using the NIST11 commercial library and an in-house mass spectral library in order to identify important analytes.
Ion Mode:POSITIVE
  logo