Return to study ST001890 main page

MB Sample ID: SA175779

Local Sample ID:1901705378
Subject ID:SU001968
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001968
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
1901705378SA175779FL02177037Gestational Age At Sampling
1901705378SA175779FL02177037Gestational Age At Delivery
1901705378SA175779FL0217701Preeclampsia

Collection:

Collection ID:CO001961
Collection Summary:Urine was collected from pregnant women
Sample Type:Urine

Treatment:

Treatment ID:TR001980
Treatment Summary:N/A

Sample Preparation:

Sampleprep ID:SP001974
Sampleprep Summary:Urine samples were thawed on ice, prepared and analyzed randomly as previously described (Contrepois et al., 2015). Briefly, urine samples were diluted 1:4 with 75% acetonitrile and 100% water for HILIC- and RPLC-MS experiments, respectively. Each sample was spiked-in with 15 analytical-grade IS.

Combined analysis:

Analysis ID AN003066 AN003067 AN003068 AN003069
Analysis type MS MS MS MS
Chromatography type HILIC HILIC Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um) EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um) Agilent Zorbax SBaq (50 x 2.1mm,1.7um) Agilent Zorbax SBaq (50 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units MS count MS count MS count MS count

Chromatography:

Chromatography ID:CH002270
Chromatography Summary:HILIC experiments were performed using a ZIC-HILIC column 2.1 x 100 mm, 3.5 μm, 200Å (Merck Millipore, Darmstadt, Germany) and mobile phase solvents consisting of 10 mM ammonium acetate in 50/50 acetonitrile/water (A) and 10 mM ammonium acetate in 95/5 acetonitrile/water (B).
Instrument Name:Thermo Dionex Ultimate 3000 RS
Column Name:EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um)
Solvent A:50% acetonitrile/50% water; 10mM ammonium acetate
Solvent B:95% acetonitrile/5% water; 10mM ammonium acetate
Chromatography Type:HILIC
  
Chromatography ID:CH002271
Chromatography Summary:RPLC experiments were performed using a Zorbax SBaq column 2.1 x 50 mm, 1.7 μm, 100Å (Agilent Technologies, Palo Alto, CA) and mobile phase solvents consisting of 0.06% acetic acid in water (A) and 0.06% acetic acid in methanol (B).
Instrument Name:Thermo Dionex Ultimate 3000 RS
Column Name:Agilent Zorbax SBaq (50 x 2.1mm,1.7um)
Solvent A:100% water; 0.06% acetic acid
Solvent B:100% methanol; 0.06% acetic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS002853
Analysis ID:AN003066
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample.
Ion Mode:POSITIVE
  
MS ID:MS002854
Analysis ID:AN003067
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample.
Ion Mode:NEGATIVE
  
MS ID:MS002855
Analysis ID:AN003068
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample.
Ion Mode:POSITIVE
  
MS ID:MS002856
Analysis ID:AN003069
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample.
Ion Mode:NEGATIVE
  logo